The DOI matches its Crossref record.
The Biofiltration of Indoor Air: Air Flux and Temperature Influences the Removal of Toluene, Ethylbenzene, and Xylene
Abstract
An alternative approach to maintaining indoor air quality may be the biofiltration of air circulated within the space. A biofilter with living botanical matter as the packing medium reduced concentrations of toluene, ethylbenzene, and o-xylene concurrently present at parts per billion (volume) in indoor air. The greatest reduction in concentrations per pass was under the slowest influent air flux (0.025 m s(-1)); however, the maximum amount removed per unit time occurred under the most rapid flux (0.2 m s(-1)). There was little difference between the different compounds with removal capacities of between 1.3 and 2.4 micromol m(-3) biofilter s(-1) (between 0.5 and 0.9 g m(-3) biofilter h(-1)) depending on influent flux and temperature. Contrary to biofilters subjected to higher influent concentrations, the optimal temperatures for removal by this biofilter decreased to less than 20 degrees C at the most rapid flux for all three compounds. Microbial activity was decreased at these cooler temperatures suggesting the biofilter was not microbially limited but rather was limited by the availability of substrate. The cooler temperatures allowed greater partitioning of the VOCs into the water column which had a greater impact on removal than its reduction in microbial activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent Advances in Petroleum Microbiology
Van Hamme, J. D., Singh, A., & Ward, O. P. (2003) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.67.4.503-549.2003 · Cited by 1,477
Biofiltration of Air: A Review
Delhoménie, M.-C., & Heitz, M. (2005) · Critical Reviews in Biotechnology · doi:10.1080/07388550590935814 · Cited by 409
The impact of greening systems on building energy performance: A literature review
Raji, B., Tenpierik, M. J., & van den Dobbelsteen, A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.02.011 · Cited by 388
Plant Species and Functional Group Combinations Affect Green Roof Ecosystem Functions
Lundholm, J., MacIvor, J. S., MacDougall, Z., & Ranalli, M. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009677 · Cited by 358
Biological treatment of indoor air for VOC removal: Potential and challenges
Guieysse, B., Hort, C., Platel, V., Munoz, R., Ondarts, M., & Revah, S. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.03.005 · Cited by 308
Torpy, F., Clements, N., Pollinger, M., Dengel, A., Mulvihill, I., He, C., & Irga, P. (2018) · Air Quality, Atmosphere & Health · doi:10.1007/s11869-017-0518-4 · Cited by 120
Cummings, B. E., & Waring, M. S. (2020) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-019-0175-9 · Cited by 98
Biotechnology Progress for Removal of Indoor Gaseous Formaldehyde
Shao, Y., Wang, Y., Zhao, R., Chen, J., Zhang, F., Linhardt, R. J., & Zhong, W. (2020) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-020-10514-1 · Cited by 76
Sharma, S., Bakht, A., Jahanzaib, M., Lee, H., & Park, D. (2022) · doi:10.21203/rs.3.rs-2091762/v1 · Cited by 44
Pettit, T., Irga, P. J., Surawski, N. C., & Torpy, F. R. (2019) · Atmosphere · doi:10.3390/atmos10120801 · Cited by 35
Metadata
- Authors
- Darlington, A. B., Dat, J. F., & Dixon, M. A.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-12-01
- Volume
- 35
- Issue
- 1
- Pages
- 240-246
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2093946942
- Cited by
- 181
- References
- 0
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.