The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrosorption of Inorganic Salts from Aqueous Solution Using Carbon Aerogels
Abstract
Capacitive deionization (CDI) with carbon aerogels has been shown to remove various inorganic species from aqueous solutions, though no studies have shown the electrosorption behavior of multisolute systems in which ions compete for limited surface area. Several experiments were conducted to determine the ion removal capacity and selectivity of carbon aerogel electrodes, using both laboratory and natural waters. Although carbon aerogel electrodes have been treated as electrical double-layer capacitors, this study showed that ion sorption followed a Langmuir isotherm, indicating monolayer adsorption. The sorption capacity of carbon aerogel electrodes was approximately 1.0-2.0 x 10(-4) equiv/g aerogel, with ion selectivity being based on ionic hydrated radius. Monovalent ions (e.g., sodium) with smaller hydrated radii were preferentially removed from solution over multivalent ions (e.g., calcium) on a percent or molar basis. Because of the relatively small average pore size (4-9 nm) of the carbon aerogel material, only 14-42 m2/g aerogel surface area was available for ion sorption. Natural organic matter may foul the aerogel surface and limit CDI effectiveness in treating natural waters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phenomenological Theory of Ion Solvation. Effective Radii of Hydrated Ions
Nightingale, E. R. (1959) · The Journal of Physical Chemistry · doi:10.1021/j150579a011 · Cited by 3,505
Cited by
Anderson, M. A., Cudero, A. L., & Palma, J. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.02.012 · Cited by 943
Advanced carbon aerogels for energy applications
Biener, J., Stadermann, M., Suss, M., Worsley, M. A., Biener, M. M., Rose, K. A., & Baumann, T. F. (2011) · Energy & Environmental Science · doi:10.1039/c0ee00627k · Cited by 651
Nanoadsorbents: Classification, Preparation, and Applications (with Emphasis on Aqueous Media)
Khajeh, M., Laurent, S., & Dastafkan, K. (2013) · Chemical Reviews · doi:10.1021/cr400086v · Cited by 528
Harvey, O. R., Herbert, B. E., Rhue, R. D., & Kuo, L.-J. (2011) · Environmental Science & Technology · doi:10.1021/es104401h · Cited by 507
Theory of membrane capacitive deionization including the effect of the electrode pore space
Biesheuvel, P. M., Zhao, R., Porada, S., & van der Wal, A. (2011) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2011.04.049 · Cited by 490
Metadata
- Authors
- Gabelich, C. J., Tran, T. D., & Suffet, I. H. “.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-05-30
- Volume
- 36
- Issue
- 13
- Pages
- 3010-3019
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1993237468
- Cited by
- 510
- References
- 1
- FWCI
- 1.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.