Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 205

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Effectiveness and Reliability of Arsenic Field Testing Kits: Are the Million Dollar Screening Projects Effective or Not?

Rahman, Mohammad Mahmudur, Mukherjee, Debapriyo, Sengupta, Mrinal Kumar, Chowdhury, Uttam Kumar, Lodh, Dilip, Chanda, Chitta Ranjan, Roy, Shibtosh, Selim, Md., Quamruzzaman, Quazi, Milton, Abul Hasnat, Shahidullah, S. M., Rahman, Md. Tofizur, Chakraborti, Dipankar·2002·Environmental Science & Technology

Abstract

The exposure of millions to arsenic contaminated water from hand tube wells is a major concern in many Asiatic countries. Field kits are currently used to classify tube wells as delivering arsenic below 50 microg/L (the recommended limit in developing countries) as safe, painted green or above 50 microg/L, unsafe and painted red. More than 1.3 million tube wells in Bangladesh alone have been tested by field kits. A few million U.S. dollars have already been spent and millions are waiting for the ongoing projects. However, the reliability of the data generated through field kits is now being questioned. Samples from 290 wells were tested by field kits and by a reliable laboratory technique to ascertain the reliability of field kits. False negatives were as high as 68% and false positives up to 35%. A statistical analysis of data from 240 and 394 other wells yielded similar rates. We then analyzed 2866 samples from previously labeled wells and found 44.9% mislabeling in the lower range (<50 microg/L) although mislabeling was considerably reduced in the higher range. Variation of analytical results due to analysts and replicates were pointed out adopting analysis of variance (ANOVA) technique. Millions of dollars are being spent without scientific validation of the field kit method. Facts and figures demand improved, environmentally friendly laboratory techniques to produce reliable data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es020591o

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 205

Metadata

Authors
Rahman, M. M., Mukherjee, D., Sengupta, M. K., Chowdhury, U. K., Lodh, D., Chanda, C. R., Roy, S., Selim, M., Quamruzzaman, Q., Milton, A. H., Shahidullah, S. M., Rahman, M. T., & Chakraborti, D.
Venue
Environmental Science & Technology
Published
2002-11-01
Volume
36
Issue
24
Pages
5385-5394
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2058275227
Cited by
205
References
1
FWCI
11.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effectiveness and Reliability of Arsenic Field Testing Kits: Are the Million Dollar Screening Projects Effective or Not? https://app.cochat.ai/papers/10.1021/es020591o
The paper
Rahman, M. M., Mukherjee, D., Sengupta, M. K., Chowdhury, U. K., Lodh, D., Chanda, C. R., Roy, S., Selim, M., Quamruzzaman, Q., Milton, A. H., Shahidullah, S. M., Rahman, M. T., & Chakraborti, D. (2002). Effectiveness and Reliability of Arsenic Field Testing Kits: Are the Million Dollar Screening Projects Effective or Not? Environmental Science & Technology. https://doi.org/10.1021/es020591o

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.