The DOI matches its Crossref record.
Mechanism of High-Temperature CO2 Sorption on Lithium Zirconate
Abstract
Lithium zirconate (Li2ZrO3) is one of the most promising materials for CO2 separation from flue gas at high temperature. This material is known to be able to absorb a large amount of CO2 at around 400-700 degrees C. However, the mechanism of the CO2 sorption/desorption process on Li2ZrO3 is not known yet. In this study, we examined the CO2 sorption/desorption mechanism on Li2ZrO3 by analyzing the phase and microstructure change of Li2ZrO3 during the CO2 sorption/desorption process with the help of thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), and X-ray diffraction (XRD) analyses. Li2ZrO3 powders were prepared from lithium carbonate (Li2CO3) and zirconium oxide (ZrO2) by the solid-state method, and the CO2 sorption/desorption property was examined by TGA. It was shown that pure Li2ZrO3 absorbs a large amount of CO2 at high temperature with a slow sorption rate. Addition of potassium carbonate (K2CO3) and Li2CO3 in the Li2ZrO3 remarkably improves the CO2 sorption rate of the Li2ZrO3 materials. DSC analysis for the CO2 sorption process indicates that doped lithium/potassium carbonate is in the liquid state during the CO2 sorption process and plays an important role in improving the CO2 uptake rate. XRD analysis for phase and structure change during the sorption/desorption process shows that the reaction between Li2ZrO3 and CO2 is reversible. Considering all data obtained in this study, we proposed a double-shell model to describe the mechanism of the CO2 sorption/desorption on both pure and modified Li2ZrO3.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
CO2 capture by solid adsorbents and their applications: current status and new trends
Wang, Q., Luo, J., Zhong, Z., & Borgna, A. (2011) · Energy Environ. Sci. · doi:10.1039/c0ee00064g · Cited by 1,611
Industrial carbon dioxide capture and utilization: state of the art and future challenges
Gao, W., Liang, S., Wang, R., Jiang, Q., Zhang, Y., Zheng, Q., Xie, B., Toe, C. Y., Zhu, X., Wang, J., et al. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00025f · Cited by 1,388
High temperature capture of CO2 on lithium-based sorbents from rice husk ash
Wang, K., Guo, X., Zhao, P., Wang, F., & Zheng, C. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.02.040 · Cited by 130
Wang, K., Zhao, P., Guo, X., Li, Y., Han, D., & Chao, Y. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.02.054 · Cited by 97
Metadata
- Authors
- Ida, J.-I., & Lin, Y. S.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-04-02
- Volume
- 37
- Issue
- 9
- Pages
- 1999-2004
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2216736963
- Cited by
- 245
- References
- 0
- FWCI
- 17.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.