The DOI matches its Crossref record.
Source Strengths for Indoor Human Activities that Resuspend Particulate Matter
Abstract
A mathematical model was applied to continuous indoor and outdoor particulate matter (PM) measurements to estimate source strengths for a variety of prescribed human activities that resuspend house dust in the home. Activities included folding blankets, folding clothes, dry dusting, making a bed, dancing on a rug, dancing on a wood floor, vacuuming, and walking around and sitting on upholstered furniture. Although most of the resuspended particle mass from these activities was larger than 5 microm in diameter, the resuspension of PM2.5 and PM5 was substantial, with source strengths ranging from 0.03 to 0.5 mg min(-1) for PM2.5 and from 0.1 to 1.4 mg min(-1) for PM5. Source strengths for PM > 5 microm could not be quantified due to instrument limitations. The source strengths were found to be a function of the number of persons performing the activity, the vigor of the activity, the type of activity, and the type of flooring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
SVOC exposure indoors: fresh look at dermal pathways: SVOC exposure via dermal pathways
Weschler, C. J., & Nazaroff, W. W. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00772.x · Cited by 422
Personal exposure monitoring of PM 2.5 in indoor and outdoor microenvironments
Steinle, S., Reis, S., Sabel, C. E., Semple, S., Twigg, M. M., Braban, C. F., Leeson, S. R., Heal, M. R., Harrison, D., Lin, C., et al. (2015) · Science of The Total Environment · doi:10.1016/j.scitotenv.2014.12.003 · Cited by 337
Particle Emission Characteristics of Office Printers
He, C., Morawska, L., & Taplin, L. (2007) · Environmental Science & Technology · doi:10.1021/es063049z · Cited by 270
Yang, F., Ding, J., Huang, W., Xie, W., & Liu, W. (2014) · Environmental Science & Technology · doi:10.1021/es403186z · Cited by 228
Particle Resuspension During the Use of Vacuum Cleaners on Residential Carpet
Corsi, R. L., Siegel, J. A., & Chiang, C. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620801901165 · Cited by 111
Characterization of coarse particulate matter in school gyms
Braniš, M., & Šafránek, J. (2011) · Environmental Research · doi:10.1016/j.envres.2011.03.010 · Cited by 86
Kopperud, R. J., Ferro, A. R., & Hildemann, L. M. (2004) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2004.10470983 · Cited by 61
Self-citationFazli, T., & Stephens, B. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.047 · Cited by 35
Metadata
- Authors
- Ferro, A. R., Kopperud, R. J., & Hildemann, L. M.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-01-31
- Volume
- 38
- Issue
- 6
- Pages
- 1759-1764
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1976273777
- Cited by
- 378
- References
- 0
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.