Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 197

The DOI matches its Crossref record.

Trace Analysis of Bromate, Chlorate, Iodate, and Perchlorate in Natural and Bottled Waters

Open access
Snyder, Shane A., Vanderford, Brett J., Rexing, David J. · 2005 · Environmental Science & Technology

Abstract

A simple and rapid method has been developed to simultaneously measure sub-microg/L quantities of the oxyhalide anions bromate, chlorate, iodate, and perchlorate in water samples. Water samples (10 mL) are passed through barium and hydronium cartridges to remove sulfate and carbonate, respectively. The method utilizes the direct injection of 10 microL volumes of water samples into a liquid chromatography-tandem triple-quadrupole mass spectrometry (LC-MS/MS) system. Ionization is accomplished using electrospray ionization in negative mode. The method detection limits were 0.021 microg/L for perchlorate, 0.045 microg/L for bromate, 0.070 microg/L for iodate, and 0.045 microg/L for chlorate anions in water. The LC-MS/MS method described here was compared to established EPA methods 300.1 and 317.1 for bromate analysis and EPA method 314.0 for perchlorate analysis. Samples collected from sites with known contamination were split and sent to certified laboratories utilizing EPA methods for bromate and perchlorate analysis. At concentrations above the reporting limits for EPA methods, the method described here was always within 20% of the established methods, and generally within 10%. Twenty-one commercially available bottled waters were analyzed for oxyhalides. The majority of bottled waters contained detectable levels of oxyhalides, with perchlorate < or = 0.74 microg/L, bromate < or = 76 microg/L, iodate < or = 25 microg/ L, and chlorate < or = 5.8 microg/L. Perchlorate, iodate, and chlorate were detectable in nearly all natural waters tested, while bromate was only detected in treated waters. Perchlorate was found in several rivers and reservoirs where itwas not found previously using EPA 314.0 (reporting limit of 4 microg/L). This method was also applied to common detergents used for cleaning laboratory glassware and equipmentto evaluate the potential for sample contamination. Only chlorate appeared as a major oxyhalide in the detergents evaluated, with concentrations up to 517 microg/g. Drinking water treatment plants were also evaluated using this method. Significant formations of chlorate and bromate are demonstrated from hypochlorite generation and ozonation. From the limited data set provided here, it appears that perchlorate is a ubiquitous contaminant of natural waters at trace levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es047935q

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Snyder, S. A., Vanderford, B. J., & Rexing, D. J.
Venue
Environmental Science & Technology
Published
2005-05-05
Volume
39
Issue
12
Pages
4586-4593
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2066331077
Cited by
197
References
0
FWCI
6.83
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.