The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Products of Ozone-Initiated Chemistry in a Simulated Aircraft Environment
Abstract
We used proton-transfer-reaction mass spectrometry (PTR-MS) to examine the products formed when ozone reacted with the materials in a simulated aircraft cabin, including a loaded high-efficiency particulate air (HEPA) filter in the return air system. Four conditions were examined: cabin (baseline), cabin plus ozone, cabin plus soiled T-shirts (surrogates for human occupants), and cabin plus soiled T-shirts plus ozone. The addition of ozone to the cabin without T-shirts, at concentrations typically encountered during commercial air travel, increased the mixing ratio (v:v concentration) of detected pollutants from 35 ppb to 80 ppb. Most of this increase was due to the production of saturated and unsaturated aldehydes and tentatively identified low-molecular-weight carboxylic acids. The addition of soiled T-shirts, with no ozone present, increased the mixing ratio of pollutants in the cabin air only slightly, whereas the combination of soiled T-shirts and ozone increased the mixing ratio of detected pollutants to 110 ppb, with more than 20 ppb originating from squalene oxidation products (acetone, 4-oxopentanal, and 6-methyl-5-hepten-2-one). For the two conditions with ozone present, the more-abundant oxidation products included acetone/propanal (8-20 ppb), formaldehyde (8-10 ppb), nonanal (approximately 6 ppb), 4-oxopentanal (3-7 ppb), acetic acid (approximately 7 ppb), formic acid (approximately 3 ppb), and 6-methyl-5-hepten-2-one (0.5-2.5 ppb), as well as compounds tentatively identified as acrolein (0.6-1 ppb) and crotonaldehyde (0.6-0.8 ppb). The odor thresholds of certain products were exceeded. With an outdoor air exchange of 3 h(-1) and a recirculation rate of 20 h(-1), the measured ozone surface removal rate constant was 6.3 h(-1) when T-shirts were not present, compared to 11.4 h(-1) when T-shirts were present.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bako-Biro, Z., Wargocki, P., Weschler, C. J., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00218.x · Cited by 180
Self-citation
Cited by
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Proton-Transfer Reaction Mass Spectrometry
Blake, R. S., Monks, P. S., & Ellis, A. M. (2009) · Chemical Reviews · doi:10.1021/cr800364q · Cited by 745
Pöschl, U., & Shiraiwa, M. (2015) · Chemical Reviews · doi:10.1021/cr500487s · Cited by 657
Weschler, C. J. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9256 · Cited by 481
Self-citation
Metadata
- Authors
- Wisthaler, A., Tamás, G., Wyon, D. P., Strøm-Tejsen, P., Space, D., Beauchamp, J., Hansel, A., Märk, T. D., & Weschler, C. J.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-06-03
- Volume
- 39
- Issue
- 13
- Pages
- 4823-4832
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2014626157
- Cited by
- 162
- References
- 1
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Products of Ozone-Initiated Chemistry in a Simulated Aircraft Environment. https://app.cochat.ai/papers/10.1021/es047992j
- The paper
- Wisthaler, A., Tamás, G., Wyon, D. P., Strøm-Tejsen, P., Space, D., Beauchamp, J., Hansel, A., Märk, T. D., & Weschler, C. J. (2005). Products of Ozone-Initiated Chemistry in a Simulated Aircraft Environment. Environmental Science & Technology. https://doi.org/10.1021/es047992j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.