Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 217 of the 217 references it cites were found in a registry or an index.

A review of the volatiles from the healthy human body

Open access
de Lacy Costello, B, Amann, A, Al-Kateb, H, Flynn, C, Filipiak, W, Khalid, T, Osborne, D, Ratcliffe, N M · 2014 · Journal of Breath Research

Abstract

A compendium of all the volatile organic compounds (VOCs) emanating from the human body (the volatolome) is for the first time reported. 1840 VOCs have been assigned from breath (872), saliva (359), blood (154), milk (256), skin secretions (532) urine (279), and faeces (381) in apparently healthy individuals. Compounds were assigned CAS registry numbers and named according to a common convention where possible. The compounds have been grouped into tables according to their chemical class or functionality to permit easy comparison. Some clear differences are observed, for instance, a lack of esters in urine with a high number in faeces. Careful use of the database is needed. The numbers may not be a true reflection of the actual VOCs present from each bodily excretion. The lack of a compound could be due to the techniques used or reflect the intensity of effort e.g. there are few publications on VOCs from blood compared to a large number on VOCs in breath. The large number of volatiles reported from skin is partly due to the methodologies used, e.g. collecting excretions on glass beads and then heating to desorb VOCs. All compounds have been included as reported (unless there was a clear discrepancy between name and chemical structure), but there may be some mistaken assignations arising from the original publications, particularly for isomers. It is the authors' intention that this database will not only be a useful database of VOCs listed in the literature, but will stimulate further study of VOCs from healthy individuals. Establishing a list of volatiles emanating from healthy individuals and increased understanding of VOC metabolic pathways is an important step for differentiating between diseases using VOCs.

Overview

Integrity signals

Registry

Crossref · 10.1088/1752-7155/8/1/014001

Cites

217 of 217 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 217 references

Research works printed but not linked: 38

  1. Sponring A, 2009, Anticancer Res., 29, 419
  2. Filipiak W, 2012, J. Breath Res., 6
  3. Schwarz K, 2009, J. Breath Res., 3
  4. Belitz H D, 2009, Food Chemistry
  5. 10.1111/j.1574-6941.1998.tb00487.x · doi:10.1111/j.1574-6941.1998.tb00487.x · Paper page
  6. Hijova E, 2007, Bratisl. Lek. Listy, 108, 354
  7. 10.1016/j.cca.2010.06.005 · DOI · Paper page
  8. Schwarz K, 2009, J. Breath Res., 3
  9. Koc H, 2011, J. Breath Res., 5
  10. King J, 2013, Physiological modeling for analysis of exhaled breath Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 27
  11. Herbig J, 2009, J. Breath Res., 3
  12. Agapiou A, 2013, Potential applications of volatile organic compounds in safety and security Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 515
  13. Spanel P, 2013, Recent SIFT-MS studies on volatile compounds in physiology, medicine and cell biology Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 48
  14. Hunter G ed Amann A, 2013, Smart sensor systems for human health breath monitoring applications Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 325
  15. Kamarchuk G, 2013, Sensors for exhaled gas analysis: an analytical review Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 264
  16. Tisch U, 2013, Arrays of nanomaterial-based sensors for breath testing Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 301
  17. Aksenov A A, 2013, Volatile organic compounds in human breath: biogenic origin and point-of-care analysis approaches Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 129
  18. Ryter S W ed Amann A, 2013, Carbon monoxide as an exhaled biomarker of pulmonary diseases Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 211
  19. Modak A ed Amann A, 2013, An update on, 244
  20. Högman M, 2013, Added value with extended NO analysis Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 194
  21. Horvath I, 2013, Exhaled nitric oxide in clinical practive: recent advances and new challenges Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 231
  22. Montuschi P ed Amann A, 2013, Measurement of biomarkers of oxidative stress and airway inflammation in exhaled breath condensate: methodology and potential applications in patients with COPD and healthy smokers Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 360
  23. Tan B K, 2012, J. Breath Res., 6
  24. Tan B K, 2010, J. Breath Res., 4
  25. Pleil J D, 2013, J. Breath Res., 7
  26. Pleil J D, 2011, J. Breath Res., 5
  27. Pleil J D, 2011, J. Breath Res., 5
  28. Pleil J D, 2013, Mathematical and statistical approaches for interpreting biomarker compounds in exhaled human breath Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 2
  29. Nogueira-Filho GR, 2008, J. Breath Res., 2
  30. Filipiak W, 2012, J. Breath Res., 6
  31. 2009, Centers for Disease Control and Prevention NHANES Fourth National Report on Human Exposure to Environmental Chemicals
  32. Kuhn E, 2001, B-0328 Rev.2.
  33. Buszewski B, 2013, Analysis of cancer biomarkers in exhaled breath and comparison with sensory indications by dogs Volatile Biomarkers: Non-invasive Diagnosis in Physiology and Medicine, 177
  34. Jenness R, 1979, Semin. Perinatol., 3, 225
  35. Smith S, 2008, J. Breath Res., 2
  36. Ruge E, 1862, Sitz.ber., Kaiserlich. Akad. Wiss., 42, 739
  37. Suarez F, 1997, Am. J. Physiol., 272, G1028
  38. De Lacy Costello B, 2008, J. Breath Res., 2

Cited by

See all 1,042

Metadata

Authors
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M.
Affiliations
  • Innsbruck Medical University (AT)
  • University of the West of England (GB)
  • University of Liverpool (GB)
Venue
Journal of Breath Research
Published
2014-01-13
Volume
8
Issue
1
Pages
014001
ISSN
  • 1752-7155 (ISSN-L)
  • 1752-7163
OpenAlex
W2102810061
Cited by
1,042
References
217
Citations by year
2026: 56 · 2025: 73 · 2024: 102 · 2023: 95 · 2022: 115 · 2021: 111 · 2020: 101 · 2019: 86 · 2018: 62 · 2017: 85 · 2016: 56 · 2015: 52 · 2014: 36
FWCI
6.56
Type
journal article
Language
en
Open access
Licence
Locations
  • Journal of Breath Research (publishedVersion)
  • PubMed (publishedVersion)
  • Bristol Research (University of Bristol) (publishedVersion)
  • UWE Research Repository (UWE Bristol) (submittedVersion, cc-by)
  • Coventry University Open Collections (Coventry university) (submittedVersion)
  • The Open Collections (Coventry University) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
  • Physical Sciences › Chemical Engineering › Process Chemistry and Technology › Odor and Emission Control Technologies
Keywords
volatile organic compounds, skin secretions, healthy individuals, disease biomarkers
MeSH terms
Body Fluids, Breath Tests, Feces, Health, Humans, Milk, Human, Human Body, Volatile Organic Compounds

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A review of the volatiles from the healthy human body. https://app.cochat.ai/papers/10.1088/1752-7155/8/1/014001
The paper
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014). A review of the volatiles from the healthy human body. Journal of Breath Research. https://doi.org/10.1088/1752-7155/8/1/014001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.