CoChat

Geographical, Spatial, and Temporal Distributions of Multiple Indoor Air Pollutants in Four Chinese Provinces

Jin, Yinlong, Zhou, Zheng, He, Gongli, Wei, Huangzhang, Liu, Jiang, Liu, Fan, Tang, Ning, Ying, Bo, Liu, Yangchang, Hu, Guohua, Wang, Hongwei, Balakrishnan, Kalpana, Watson, Kimber, Baris, Enis, Ezzati, Majid · 2005 · Environmental Science & Technology
Cited by 86

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Exposure to indoor air pollution from household energy use depends on fuel, stove, housing characteristics, and stove use behavior. We monitored three important indoor air pollutants-respirable particles (RPM), carbon monoxide (CO), and sulfur dioxide (SO2)-for a total of 457 household-days in four poor provinces in China (Gansu, 129 household-days; Guizhou, 127 household-days; Inner Mongolia, 65 household-days; and Shaanxi, 136 household-days), in two time intervals during the heating season to investigate spatial and temporal patterns of pollution. The two provinces where biomass is the primary fuel (Inner Mongolia and Gansu) had the highest RPM concentrations (719 microg/m3 in the single cooking/living/bedroom in Inner Mongolia in December and 351-661 microg/m3 in different rooms and months in Gansu); lower RPM concentration were observed in the primarily coal-burning provinces of Guizhou and Shaanxi (202-352 microg/m3 and 187-361 microg/m3 in different rooms and months in Guizhou and Shaanxi, respectively). Inner Mongolia and Gansu also had higher CO concentrations (7.4 ppm in the single cooking/living/bedroom in Inner Mongolia in December and 4.8-11.3 ppm in different rooms and months in Gansu). Among the two primarily coal-burning provinces, Guizhou had lower concentrations of CO than Shaanxi (1.2-1.8 ppm in Guizhou vs 2.0-13.3 ppm in different rooms and months in Shaanxi). In the two coal-burning provinces, SO2 concentrations were substantially higher in Shaanxi than in Guizhou. Relative concentrations in different rooms and provinces indicate that in the northern provinces heating is an important source of exposure to indoor pollutants from energy use. Day-to-day variability of concentrations within individual households, although substantial, was smaller than variation across households. The implications of the findings for designing environmental health interventions in each province are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es0507517

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 86

Metadata

Authors
Jin, Y., Zhou, Z., He, G., Wei, H., Liu, J., Liu, F., Tang, N., Ying, B., Liu, Y., Hu, G., Wang, H., Balakrishnan, K., Watson, K., Baris, E., & Ezzati, M.
Venue
Environmental Science & Technology
Published
2005-11-16
Volume
39
Issue
24
Pages
9431-9439
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2012561989
Cited by
86
References
1
FWCI
6.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Geographical, Spatial, and Temporal Distributions of Multiple Indoor Air Pollutants in Four Chinese Provinces. https://app.cochat.ai/papers/10.1021/es0507517
The paper
Jin, Y., Zhou, Z., He, G., Wei, H., Liu, J., Liu, F., Tang, N., Ying, B., Liu, Y., Hu, G., Wang, H., Balakrishnan, K., Watson, K., Baris, E., & Ezzati, M. (2005). Geographical, Spatial, and Temporal Distributions of Multiple Indoor Air Pollutants in Four Chinese Provinces. Environmental Science & Technology. https://doi.org/10.1021/es0507517

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.