Reaction Mechanism and Kinetic Modeling of DEET Degradation by Flow-Through Anodic Fenton Treatment (FAFT)
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The previously developed batch anodic Fenton treatment (AFT) technology has been successfully applied to degrade various pesticides in aqueous solution. The goal of this work is the development of a flow-through AFT system (FAFT) which is critical to bringing this technology into practical general use in the field. For this purpose, the degradation of DEET (N,N-diethyl-3-methylbenzamide), an insect repellent, and nine model amides was studied. Oxidation products of these compounds in FAFT were identified by GC/MS, and the results revealed that various -OH additions (most likely on the aromatic ring), quinone/keto product formation, and dimerization/bimolecular disproportionation are the major reaction pathways. This proposed overall reaction mechanism was then combined with the basic Fenton's mechanism to model the kinetics of various active species in FAFT including DEET, Fe2+, H2O2, and total iron under different reaction conditions. In addition, both initial and steady-state hydroxyl radical concentrations were measured in FAFT using benzoic acid as a chemical probe; the measured *OH concentrations were best-fitted exponentially. On the basis of the obtained [*OH] trend and the mass balance of the FAFT system, a simple FAFT model was developed to fit all of the degradation data of DEET and the model amides.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
De Laat, J., & Gallard, H. (1999) · Environmental Science & Technology · doi:10.1021/es981171v · Cited by 749
Cited by
Electro-Fenton Process and Related Electrochemical Technologies Based on Fenton’s Reaction Chemistry
Brillas, E., Sirés, I., & Oturan, M. A. (2009) · Chemical Reviews · doi:10.1021/cr900136g · Cited by 3,437
Keenan, C. R., & Sedlak, D. L. (2008) · Environmental Science & Technology · doi:10.1021/es7025664 · Cited by 730
Ganiyu, S. O., van Hullebusch, E. D., Cretin, M., Esposito, G., & Oturan, M. A. (2015) · Separation and Purification Technology · doi:10.1016/j.seppur.2015.09.059 · Cited by 627
Fe(II) Redox Chemistry in the Environment
Huang, J., Jones, A., Waite, T. D., Chen, Y., Huang, X., Rosso, K. M., Kappler, A., Mansor, M., Tratnyek, P. G., & Zhang, H. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01286 · Cited by 620
Self-citationMn-based catalysts for sulfate radical-based advanced oxidation processes: A review
Huang, J., & Zhang, H. (2019) · Environment International · doi:10.1016/j.envint.2019.105141 · Cited by 328
Self-citation
Metadata
- Authors
- Zhang, H., & Lemley, A. T.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-06-07
- Volume
- 40
- Issue
- 14
- Pages
- 4488-4494
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2010354928
- Cited by
- 44
- References
- 1
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reaction Mechanism and Kinetic Modeling of DEET Degradation by Flow-Through Anodic Fenton Treatment (FAFT). https://app.cochat.ai/papers/10.1021/es060515b
- The paper
- Zhang, H., & Lemley, A. T. (2006). Reaction Mechanism and Kinetic Modeling of DEET Degradation by Flow-Through Anodic Fenton Treatment (FAFT). Environmental Science & Technology. https://doi.org/10.1021/es060515b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.