CoChat

Catalytic Decomposition of Hydrogen Peroxide by Fe(III) in Homogeneous Aqueous Solution: Mechanism and Kinetic Modeling

De Laat, Joseph, Gallard, HervÉ · 1999 · Environmental Science & Technology

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

This paper describes a kinetic model for the decomposition of hydrogen peroxide by ferric ion in homogeneous aqueous solution (pH < 3). The reaction was investigated experimentally at 25.0 °C and I = 0.1 M (HClO 4 /NaClO 4 ), in a completely mixed batch reactor and under a wide range of experimental conditions (1 ≤ pH ≤ 3; 0.2 mM ≤ [H 2 O 2 ] 0 ≤ 1 M; 50 μM ≤ [Fe(III)] 0 ≤ 1 mM; 1 ≤ [H 2 O 2 ] 0 /[Fe(III)] 0 ≤ 5000). The results of this study demonstrated that the rate of decomposition of hydrogen peroxide by Fe(III) could be predicted very accurately by a kinetic model which takes into account the rapid formation and the slower decomposition of Fe(III)−hydroperoxy complexes (Fe III (HO 2 ) 2+ and Fe III (OH)(HO 2 ) + ). The rate constant for the unimolecular decomposition of the Fe(III)−hydroperoxy complexes was determined to be 2.7 × 10 - 3 s - 1 . The use of the kinetic model allows a better understanding of the effects of operational parameters (i.e., pH and [H 2 O 2 ] 0 /[Fe(III)] 0 ) on the complex kinetics of decomposition of H 2 O 2 by Fe(III).

Overview

Integrity signals

Registry

Crossref · 10.1021/es981171v

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 28 references

Research works printed but not linked: 13

  1. Haber F., 1934, Proc. Roy. Soc. A, 134, 351
  2. Cohen G., 1980, Dev. Biochem., 11, 37
  3. Eisenhauer H. R., 1964, J.Water Pollut. Control Fed., 36, 1128
  4. Safarzadeh-Amiri A., 1996, J. Adv. Oxid. Technol., 1, 26
  5. Jones P., 1959, Trans. Faraday Soc., 55, 90
  6. Lewis T. J., 1963, J. Chem. Soc., 2434, 2442
  7. Gallard H., Water Res
  8. Gallard H., 1998, New J. Chem., 263, 268
  9. Stuglik Z., 1981, Radiat. Phys. Chem., 17, 233
  10. Jayson G. G., 1973, J. Chem. Soc., Faraday Trans I, 69, 242
  11. Bielski B. H. J., 1985, J. Phys. Chem. Ref. Data, 14, 1100
  12. 1990, Eaux méthodes d'essai − recueil de normes françaises
  13. Eisenberg G. M., 1943, Ind. Eng. Chem., 15, 328

Cited by

See all 767

Metadata

Authors
De Laat, J., & Gallard, H.
Affiliations
  • Laboratoire de Chimie de l'Eau et de l'Environnement, CNRS UPRESA 6008, Ecole Supérieure d'Ingénieurs de Poitiers, Université de Poitiers, 40, avenue du Recteur Pineau, 86 022 Poitiers Cedex, France
  • Centre National de la Recherche Scientifique (FR)
Venue
Environmental Science & Technology
Published
1999-07-02
Volume
33
Issue
16
Pages
2726-2732
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2083669451
Cited by
749
References
28
Citations by year
2026: 20 · 2025: 34 · 2024: 19 · 2023: 30 · 2022: 36 · 2021: 47 · 2020: 44 · 2019: 37 · 2018: 36 · 2017: 39 · 2016: 45 · 2015: 31 · 2014: 36 · 2013: 29 · 2012: 24
FWCI
16.27
Type
journal article
Language
en
Open access
closed
Locations
Environmental Science & Technology (publishedVersion)
Topics
  • Physical Sciences › Environmental Science › Water Science and Technology › Advanced oxidation water treatment
  • Physical Sciences › Chemistry › Organic Chemistry › Free Radicals and Antioxidants
  • Physical Sciences › Environmental Science › Water Science and Technology › Coagulation and Flocculation Studies
Keywords
hydrogen peroxide decomposition, iron(III), reaction mechanism, kinetic modeling, pH effect

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Catalytic Decomposition of Hydrogen Peroxide by Fe(III) in Homogeneous Aqueous Solution: Mechanism and Kinetic Modeling. https://app.cochat.ai/papers/10.1021/es981171v
The paper
De Laat, J., & Gallard, H. (1999). Catalytic Decomposition of Hydrogen Peroxide by Fe(III) in Homogeneous Aqueous Solution: Mechanism and Kinetic Modeling. Environmental Science & Technology. https://doi.org/10.1021/es981171v

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.