An In Vivo Multiwell-Based Fluorescent Screen for Monitoring Vertebrate Thyroid Hormone Disruption

Fini, Jean-Baptiste, Le Mével, Sébastien, Turque, Nathalie, Palmier, Karima, Zalko, Daniel, Cravedi, Jean-Pierre, Demeneix, Barbara A. · 2007 · Environmental Science & Technology
Cited by 133

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

There is a pressing need for high throughput methods to assess potential effects of endocrine disrupting chemicals (EDCs). released into the environment. Currently our ability to identify effects in vitro exceeds that for in vivo monitoring. However, only in vivo analysis provides the full spectrum of physiological impacts exerted by a given chemical. With the aim of finding a physiological system compatible with automatic plate reading we tested the capacity of early embryonic stage Xenopus laevis tadpoles to monitor thyroid hormone (TH) disruption. Fluorescent transgenic X. laevis embryos bearing a TH/bZIP-eGFP construct, placed in 96 well plates, were used for a physiological-based screen for potential TH signaling disruptors. Using stage NF-45 embryos (time of thyroid gland formation) allowed rapid detection of chemical interference with both peripheral TR signaling and production of endogenous TH. Nanomolar concentrations of TH receptor agonists could be detected within 72 h. Moreover, when testing against a 5nM T3 challenge, the effects of inhibitors of TH production were revealed, including inhibitors of TH synthesis, (methimazole: 1 mM or sodium perchlorate: 3.56 microM), as well as antagonists acting at the receptor level (NH3: 2 microM) and a deiodinase inhibitor (iopanoic acid: 10 microM). Finally, we show that the thyroid disrupting activities of BPA (10 microM) and TBBPA (1 microM) can also be detected in this rapid screening protocol. Finally, this noninvasive technology using an automatic reading system shows low variability (around 5%) and permits detection of subtle changes in signaling by EDCs that either inhibit or activate TH signaling in vivo.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es0704129

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 133

Metadata

Authors
Fini, J.-B., Le Mével, S., Turque, N., Palmier, K., Zalko, D., Cravedi, J.-P., & Demeneix, B. A.
Venue
Environmental Science & Technology
Published
2007-07-20
Volume
41
Issue
16
Pages
5908-5914
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W1992944847
Cited by
133
References
3
FWCI
4.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An In Vivo Multiwell-Based Fluorescent Screen for Monitoring Vertebrate Thyroid Hormone Disruption. https://app.cochat.ai/papers/10.1021/es0704129
The paper
Fini, J.-B., Le Mével, S., Turque, N., Palmier, K., Zalko, D., Cravedi, J.-P., & Demeneix, B. A. (2007). An In Vivo Multiwell-Based Fluorescent Screen for Monitoring Vertebrate Thyroid Hormone Disruption. Environmental Science & Technology. https://doi.org/10.1021/es0704129

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.