Incoherent Broadband Cavity-Enhanced Absorption Spectroscopy in the near-Ultraviolet: Application to HONO and NO2
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The first application of incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) in the near-ultraviolet for the simultaneous detection of two key atmospheric trace species, HONO and NO2, is reported. For both compounds the absorption is measured between 360 and 380 nm with a compact cavity-enhanced spectrometer employing a high power light-emitting diode. Detection limits of approximately 4 ppbv for HONO and approximately 14 ppbv for NO2 are reported for a static gas cell setup using a 20 s acquisition time. Based on an acquisition time of 10 min and an optical cavity length of 4.5 m detection limits of approximately 0.13 ppbv and approximately 0.38 ppbv were found for HONO and NO2 in a 4 m3 atmospheric simulation chamber, demonstrating the usefulness of this approach for in situ monitoring of these important species in laboratory studies or field campaigns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
The HITRAN 2004 molecular spectroscopic database
Rothman, L. S., Jacquemart, D., Barbe, A., Chris Benner, D., Birk, M., Brown, L. R., Carleer, M. R., Chackerian, C., Chance, K., Coudert, L. H., et al. (2005) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2004.10.008 · Cited by 2,545
Self-citationFinlayson-Pitts, B. J., Wingen, L. M., Sumner, A. L., Syomin, D., & Ramazan, K. A. (2003) · Physical Chemistry Chemical Physics · doi:10.1039/b208564j · Cited by 691
BURROWS, J. P., RICHTER, A., DEHN, A., DETERS, B., HIMMELMANN, S., VOIGT, S., & ORPHAL, J. (1999) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/s0022-4073(98)00037-5 · Cited by 466
Self-citationEvaluation of nitrogen dioxide chemiluminescence monitors in a polluted urban environment
Dunlea, E. J., Herndon, S. C., Nelson, D. D., Volkamer, R. M., San Martini, F., Sheehy, P. M., Zahniser, M. S., Shorter, J. H., Wormhoudt, J. C., Lamb, B. K., et al. (2007) · Atmospheric Chemistry and Physics · doi:10.5194/acp-7-2691-2007 · Cited by 419
Detection of nitrous acid in the atmosphere by differential optical absorption
Perner, D., & Platt, U. (1979) · Geophysical Research Letters · doi:10.1029/gl006i012p00917 · Cited by 414 · cited 1×
“The detection limit of the chamber B experiment can be compared with those of numerous other approaches to monitor HONO: (i) Optical methods : Long-path DOAS systems have been used to monitor HONO and NO 2 in the atmosphere for several decades (28-31).”
MethodDirect measurement of the Rayleigh scattering cross section in various gases
Sneep, M., & Ubachs, W. (2005) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2004.07.025 · Cited by 369
Incoherent broad-band cavity-enhanced absorption spectroscopy
Fiedler, S. E., Hese, A., & Ruth, A. A. (2003) · Chemical Physics Letters · doi:10.1016/s0009-2614(03)00263-x · Cited by 359 · cited 2×
“The absorption coefficient of the gas mixture inside the cavity was determined using (18): #1 The adjacent absorption peaks of HONO at 354 nm and 383 nm were also observed, but the signal-to-noise ratio of these absorption features was significantly worse owing to the lower LED intensity at these…”
MethodSelf-citationA New Instrument To Measure Gaseous Nitrous Acid (HONO) in the Atmosphere
Heland, J., Kleffmann, J., Kurtenbach, R., & Wiesen, P. (2001) · Environmental Science & Technology · doi:10.1021/es000303t · Cited by 331 · cited 3×
“(iv) Chemically interfering species, which mostly affect wet chemical approaches (35,38,50-52), can be accounted for in the data analysis.”
BackgroundMethodHarris, G. W., Carter, W., Winer, A. M., PITTS, J. N. J., Platt, U., & Perner, D. (1982) · Environmental Science & Technology · doi:10.1021/es00101a009 · Cited by 309
BURROWS, J. P., DEHN, A., DETERS, B., HIMMELMANN, S., RICHTER, A., VOIGT, S., & ORPHAL, J. (1998) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/s0022-4073(97)00197-0 · Cited by 224
Self-citationContribution of HONO sources to the NOx/HOx/O3 chemistry in the polluted boundary layer
Aumont, B., Chervier, F., & Laval, S. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00920-2 · Cited by 213
An evaluation of the mechanism of nitrous acid formation in the urban atmosphere
Calvert, J. G., Yarwood, G., & Dunker, A. M. (1994) · Research on Chemical Intermediates · doi:10.1163/156856794x00423 · Cited by 210 · cited 1×
“HONO may be formed by two different reactions under our experimental conditions (22,23): For reaction R2 light is not essential but it increases the reaction rate of HONO formation (24).”
BackgroundVogel, B., Vogel, H., Kleffmann, J., & Kurtenbach, R. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(03)00243-7 · Cited by 180 · cited 1×
“Although it is generally agreed that heterogeneous NO 2 chemistry is probably the most important source of HONO (3,4), modelled HONO concentrations are often significantly below observed values (5,6).”
BackgroundBroadband cavity enhanced absorption spectroscopy using light emitting diodes
Ball, S. M., Langridge, J. M., & Jones, R. L. (2004) · Chemical Physics Letters · doi:10.1016/j.cplett.2004.08.144 · Cited by 171
Evidence for a surface source of atmospheric nitrous acid
Harrison, R. M., & Kitto, A. N. (1994) · Atmospheric Environment · doi:10.1016/1352-2310(94)90286-0 · Cited by 168 · cited 1×
“Although it is generally agreed that heterogeneous NO 2 chemistry is probably the most important source of HONO (3,4), modelled HONO concentrations are often significantly below observed values (5,6).”
BackgroundA long-path infra-red study of Los Angeles smog
Hanst, P. L., Wong, N. W., & Bragin, J. (1982) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(82)90183-4 · Cited by 165 · cited 1×
“In the laboratory Fourier transform infrared spectroscopy (33) and cavity ring-down spectroscopy (34) have also been used for absorption measurements of HONO with detection limits of ~5 ppbv for acquisition times of ca. 20 min and 15 s, respectively.”
MethodBroad-Band Cavity Ring-Down Spectroscopy
Ball, S. M., & Jones, R. L. (2003) · Chemical Reviews · doi:10.1021/cr020523k · Cited by 157 · cited 1×
“Monitoring multiple species with good time resolution is also difficult to realize with CRDS unless a broadband approach is taken (17).”
BackgroundSaiz‐Lopez, A., Plane, J. M. C., McFiggans, G. B., Williams, P. I., Ball, S. M., Bitter, M., Jones, R. L., Hongwei, C., & Hoffmann, T. (2006) · Atmospheric chemistry and physics · doi:10.5194/acp-6-883-2006 · Cited by 153
Simultaneous in situ detection of atmospheric NO3 and N2O5 via cavity ring-down spectroscopy
Brown, S. S., Stark, H., Ciciora, S. J., McLaughlin, R. J., & Ravishankara, A. R. (2002) · Review of Scientific Instruments · doi:10.1063/1.1499214 · Cited by 142
Venables, D. S., Gherman, T., Orphal, J., Wenger, J., & Ruth, A. A. (2006) · Environmental Science & Technology · doi:10.1021/es061076j · Cited by 124
Self-citationBaynard, T., Lovejoy, E. R., Pettersson, A., Brown, S. S., Lack, D. A., Osthoff, H. D., Massoli, P., Ciciora, S. J., Dubé, W. P., & Ravishankara, A. R. (2007) · Aerosol Science and Technology · doi:10.1080/02786820701222801 · Cited by 121
Bröske, R., Kleffmann, J., & Wiesen, P. (2003) · Atmospheric chemistry and physics · doi:10.5194/acp-3-469-2003 · Cited by 90
Cavity-enhanced absorption spectroscopy with a red LED source for NOx trace analysis
Triki, M., Čermák, P., Méjean, G., & Romanini, D. (2008) · Applied Physics B · doi:10.1007/s00340-008-2958-x · Cited by 73
Kern, C., Trick, S., Rippel, B., & Platt, U. (2006) · Applied Optics · doi:10.1364/ao.45.002077 · Cited by 65
A Method for the Measurement of Atmospheric HONO Based on DNPH Derivatization and HPLC Analysis
Zhou, X., Qiao, H., Deng, G., & Civerolo, K. L. (1999) · Environmental Science & Technology · doi:10.1021/es981304c · Cited by 57 · cited 2×
“(iv) Chemically interfering species, which mostly affect wet chemical approaches (35,38,50-52), can be accounted for in the data analysis.”
BackgroundMethodChemiluminescent method for continuous monitoring of nitrous acid in ambient air
Kanda, Y., & Taira, M. (1990) · Analytical Chemistry · doi:10.1021/ac00218a007 · Cited by 55
Measurement of high concentration of nitrous acid inside automobiles
Febo, A., & Perrino, C. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(94)00260-r · Cited by 42
Cited by
Hodgkinson, J., & Tatam, R. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,745
Burling, I. R., Yokelson, R. J., Griffith, D. W. T., Johnson, T. J., Veres, P., Roberts, J. M., Warneke, C., Urbanski, S. P., Reardon, J., Weise, D. R., et al. (2010) · Atmospheric Chemistry and Physics · doi:10.5194/acp-10-11115-2010 · Cited by 272
Roberts, J. M., Veres, P., Warneke, C., Neuman, J. A., Washenfelder, R. A., Brown, S. S., Baasandorj, M., Burkholder, J. B., Burling, I. R., Johnson, T. J., et al. (2010) · Atmospheric Measurement Techniques · doi:10.5194/amt-3-981-2010 · Cited by 192
“IBBCEAS employs broadband light that is coupled into a high-finesse optical cavity to achieve a long effective pathlength, and has been used previously for measurements of HONO (Gherman et al., 2008; Langridge et al., 2009).”
Method
Metadata
- Authors
- Gherman, T., Venables, D. S., Vaughan, S., Orphal, J., & Ruth, A. A.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-12-28
- Volume
- 42
- Issue
- 3
- Pages
- 890-895
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2016525938
- Cited by
- 158
- References
- 28
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.