CoChat

Simultaneous in situ detection of atmospheric NO3 and N2O5 via cavity ring-down spectroscopy

Brown, Steven S., Stark, Harald, Ciciora, Steven J., McLaughlin, Richard J., Ravishankara, A. R. · 2002 · Review of Scientific Instruments
Cited by 142

The DOI matches its Crossref record.

Abstract

This article describes the application of cavity ring-down spectroscopy (CaRDS) to the simultaneous concentration measurement of nitrate radical, NO3, and dinitrogen pentoxide, N2O5, in the ambient atmosphere. The sensitivity for detection of both NO3 and N2O5 is 0.5 pptv (2σ) for a 5 s integration, comparable to or better than previous measurements of NO3 (e.g., via DOAS), but with significantly better time resolution. Furthermore, direct measurement of N2O5 represent a previously unavailable capability. Concentrations of both species are measured simultaneously in two separate flow systems and optical cavities pumped by the same pulsed dye laser at 662 nm. One of the flow systems remains at ambient temperature for detection of NO3, while the other is heated to 80 °C to induce thermal decomposition of N2O5 providing a measurement of the sum of the NO3 and N2O5 concentrations. This article outlines a series of laboratory and field tests of the instrument’s performance. Important considerations include signal acquisition, zero measurements, aerosol interference, flow system losses, and the conversion efficiency for N2O5 thermolysis to NO3. We describe the limitations of this method and show how they can be quantified and accounted for in field measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1499214

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 142

Metadata

Authors
Brown, S. S., Stark, H., Ciciora, S. J., McLaughlin, R. J., & Ravishankara, A. R.
Venue
Review of Scientific Instruments
Published
2002-09-01
Volume
73
Issue
9
Pages
3291-3301
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W1888755143
Cited by
142
References
0
FWCI
3.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous in situ detection of atmospheric NO3 and N2O5 via cavity ring-down spectroscopy. https://app.cochat.ai/papers/10.1063/1.1499214
The paper
Brown, S. S., Stark, H., Ciciora, S. J., McLaughlin, R. J., & Ravishankara, A. R. (2002). Simultaneous in situ detection of atmospheric NO3 and N2O5 via cavity ring-down spectroscopy. Review of Scientific Instruments. https://doi.org/10.1063/1.1499214

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.