The DOI matches its Crossref record.
Electrical Power from Sea and River Water by Reverse Electrodialysis: A First Step from the Laboratory to a Real Power Plant
Abstract
Electricity can be produced directly with reverse electrodialysis (RED) from the reversible mixing of two solutions of different salinity, for example, sea and river water. The literature published so far on RED was based on experiments with relatively small stacks with cell dimensions less than 10 × 10 cm(2). For the implementation of the RED technique, it is necessary to know the challenges associated with a larger system. In the present study we show the performance of a scaled-up RED stack, equipped with 50 cells, each measuring 25 × 75 cm(2). A single cell consists of an AEM (anion exchange membrane) and a CEM (cation exchange membrane) and therefore, the total active membrane area in the stack is 18.75 m(2). This is the largest dimension of a reverse electrodialysis stack published so far. By comparing the performance of this stack with a small stack (10 × 10 cm(2), 50 cells) it was found that the key performance parameter to maximal power density is the hydrodynamic design of the stack. The power densities of the different stacks depend on the residence time of the fluids in the stack. For the large stack this was negatively affected by the increased hydrodynamic losses due to the longer flow path. It was also found that the large stack generated more power when the sea and river water were flowing in co-current operation. Co-current flow has other advantages, the local pressure differences between sea and river water compartments are low, hence preventing leakage around the internal manifolds and through pinholes in the membranes. Low pressure differences also enable the use of very thin membranes (with low electrical resistance) as well as very open spacers (with low hydrodynamic losses) in the future. Moreover, we showed that the use of segmented electrodes increase the power output by 11%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Membrane-based processes for sustainable power generation using water
Logan, B. E., & Elimelech, M. (2012) · Nature · doi:10.1038/nature11477 · Cited by 1,644
New avenues for the large-scale harvesting of blue energy
Siria, A., Bocquet, M.-L., & Bocquet, L. (2017) · Nature Reviews Chemistry · doi:10.1038/s41570-017-0091 · Cited by 640
Campione, A., Gurreri, L., Ciofalo, M., Micale, G., Tamburini, A., & Cipollina, A. (2018) · Desalination · doi:10.1016/j.desal.2017.12.044 · Cited by 588
Recent developments and future perspectives of reverse electrodialysis technology: A review
Mei, Y., & Tang, C. Y. (2018) · Desalination · doi:10.1016/j.desal.2017.10.021 · Cited by 499
Membrane technology in renewable-energy-driven desalination
Ali, A., Tufa, R. A., Macedonio, F., Curcio, E., & Drioli, E. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.047 · Cited by 431
2D materials as an emerging platform for nanopore-based power generation
Macha, M., Marion, S., Nandigana, V. V. R., & Radenovic, A. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0126-z · Cited by 426
Doubled Power Density from Salinity Gradients at Reduced Intermembrane Distance
Vermaas, D. A., Saakes, M., & Nijmeijer, K. (2011) · Environmental Science & Technology · doi:10.1021/es2012758 · Cited by 411
Self-citationTufa, R. A., Pawlowski, S., Veerman, J., Bouzek, K., Fontananova, E., di Profio, G., Velizarov, S., Goulão Crespo, J., Nijmeijer, K., & Curcio, E. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.04.111 · Cited by 312
Self-citationNam, J.-Y., Cusick, R. D., Kim, Y., & Logan, B. E. (2012) · Environmental Science & Technology · doi:10.1021/es300228m · Cited by 105
Metadata
- Authors
- Veerman, J., Saakes, M., Metz, S. J., & Harmsen, G. J.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-10-21
- Volume
- 44
- Issue
- 23
- Pages
- 9207-9212
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2133324084
- Cited by
- 276
- References
- 0
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.