The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Enzyme-Immobilized Nanofiltration Membrane To Mitigate Biofouling Based on Quorum Quenching
Abstract
Recently, enzymatic quorum quenching (in the form of a free enzyme or an immobilized form on a bead) was successfully applied to a submerged membrane bioreactor with a microfiltration membrane for wastewater treatment as a novel approach to control membrane biofouling. In this study, a quorum quenching enzyme (acylase) was directly immobilized onto a nanofiltration membrane to mitigate biofouling in a nanofiltration process. In a flow cell experiment, the acylase-immobilized membrane with quorum quenching activity prohibited the formation of mushroom-shaped mature biofilm due to the reduced secretion of extracellular polymeric substances (EPS). The acylase-immobilized membrane maintained more than 90% of its initial enzyme activity for more than 20 iterative cycles of reaction and washing procedure. In the lab-scale continuous crossflow nanofiltration system operated at a constant pressure of 2 bar, the flux with the acylase-immobilized nanofiltration (NF) membrane was maintained at more than 90% of its initial flux after a 38-h operation, whereas that with the raw NF membrane decreased to 60% accompanied with severe biofouling. The quorum quenching activity of the acylase-immobilized membrane was also confirmed by visualizing the spatial distribution of cells and polysaccharides on the surface of each membrane using confocal laser scanning microscopy (CLSM) image analysis technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Involvement of Cell-to-Cell Signals in the Development of a Bacterial Biofilm
Davies, D. G., Parsek, M. R., Pearson, J. P., Iglewski, B. H., Costerton, J. W., & Greenberg, E. P. (1998) · Science · doi:10.1126/science.280.5361.295 · Cited by 3,396
Cited by
Fouling in membrane bioreactors: An updated review
Meng, F., Zhang, S., Oh, Y., Zhou, Z., Shin, H.-S., & Chae, S.-R. (2017) · Water Research · doi:10.1016/j.watres.2017.02.006 · Cited by 1,078
Quorum sensing inhibitors: An overview
Kalia, V. C. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2012.10.004 · Cited by 971
Rocchitta, G., Spanu, A., Babudieri, S., Latte, G., Madeddu, G., Galleri, G., Nuvoli, S., Bagella, P., Demartis, M., Fiore, V., et al. (2016) · Sensors · doi:10.3390/s16060780 · Cited by 555
Shi, Y., Huang, J., Zeng, G., Gu, Y., Chen, Y., Hu, Y., Tang, B., Zhou, J., Yang, Y., & Shi, L. (2017) · Chemosphere · doi:10.1016/j.chemosphere.2017.04.042 · Cited by 497
Membrane Bioreactor (MBR) Technology for Wastewater Treatment and Reclamation: Membrane Fouling
Iorhemen, O., Hamza, R., & Tay, J. (2016) · Membranes · doi:10.3390/membranes6020033 · Cited by 483
Metadata
- Authors
- Kim, J.-H., Choi, D.-C., Yeon, K.-M., Kim, S.-R., & Lee, C.-H.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-01-04
- Volume
- 45
- Issue
- 4
- Pages
- 1601-1607
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1986970550
- Cited by
- 223
- References
- 1
- FWCI
- 12.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enzyme-Immobilized Nanofiltration Membrane To Mitigate Biofouling Based on Quorum Quenching. https://app.cochat.ai/papers/10.1021/es103483j
- The paper
- Kim, J.-H., Choi, D.-C., Yeon, K.-M., Kim, S.-R., & Lee, C.-H. (2011). Enzyme-Immobilized Nanofiltration Membrane To Mitigate Biofouling Based on Quorum Quenching. Environmental Science & Technology. https://doi.org/10.1021/es103483j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.