Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Intake Fraction for Particulate Matter: Recommendations for Life Cycle Impact Assessment

Humbert, Sebastien, Marshall, Julian D., Shaked, Shanna, Spadaro, Joseph V., Nishioka, Yurika, Preiss, Philipp, McKone, Thomas E., Horvath, Arpad, Jolliet, Olivier·2011·Environmental Science & Technology

Abstract

Particulate matter (PM) is a significant contributor to death and disease globally. This paper summarizes the work of an international expert group on the integration of human exposure to PM into life cycle impact assessment (LCIA), within the UNEP/SETAC Life Cycle Initiative. We review literature-derived intake fraction values (the fraction of emissions that are inhaled), based on emission release height and "archetypal" environment (indoor versus outdoor; urban, rural, or remote locations). Recommended intake fraction values are provided for primary PM(10-2.5) (coarse particles), primary PM(2.5) (fine particles), and secondary PM(2.5) from SO(2), NO(x), and NH(3). Intake fraction values vary by orders of magnitude among conditions considered. For outdoor primary PM(2.5), representative intake fraction values (units: milligrams inhaled per kilogram emitted) for urban, rural, and remote areas, respectively, are 44, 3.8, and 0.1 for ground-level emissions, versus 26, 2.6, and 0.1 for an emission-weighted stack height. For outdoor secondary PM, source location and source characteristics typically have only a minor influence on the magnitude of the intake fraction (exception: intake fraction values can be an order of magnitude lower for remote-location emission than for other locations). Outdoor secondary PM(2.5) intake fractions averaged over respective locations and stack heights are 0.89 (from SO(2)), 0.18 (NO(x)), and 1.7 (NH(3)). Estimated average intake fractions are greater for primary PM(10-2.5) than for primary PM(2.5) (21 versus 15), owing in part to differences in average emission height (lower, and therefore closer to people, for PM(10-2.5) than PM(2.5)). For indoor emissions, typical intake fraction values are ∼1000-7000. This paper aims to provide as complete and consistent an archetype framework as possible, given current understanding of each pollutant. Values presented here facilitate incorporating regional impacts into LCIA for human health damage from PM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es103563z

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Humbert, S., Marshall, J. D., Shaked, S., Spadaro, J. V., Nishioka, Y., Preiss, P., McKone, T. E., Horvath, A., & Jolliet, O.
Venue
Environmental Science & Technology
Published
2011-05-12
Volume
45
Issue
11
Pages
4808-4816
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2324080358
Cited by
174
References
2
FWCI
7.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.