The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Series Assembly of Microbial Desalination Cells Containing Stacked Electrodialysis Cells for Partial or Complete Seawater Desalination
Abstract
A microbial desalination cell (MDC) is a new approach for desalinating water based on using the electrical current generated by exoelectrogenic bacteria. Previously developed MDCs have used only one or two desalination chambers with substantial internal resistance, and used low salinity catholytes containing a buffered or acid solution. Here we show that substantially improved MDC performance can be obtained even with a nonbuffered, saline catholyte, by using an electrodialysis stack consisting of 5 pairs of desalting and concentrating cells. When 4 stacked MDCs were used in series (20 total pairs of desalination chambers), the salinity of 0.06 L of synthetic seawater (35 g/L NaCl) was reduced by 44% using 0.12 L of anode solution (2:1). The resistive loss in the electrodialysis stack was negligible due to minimization of the intermembrane distances, and therefore the power densities produced by the MDC were similar to those produced by single chamber microbial fuel cells (MFCs) lacking desalination chambers. The observed current efficiency was 86%, indicating separation of 4.3 pairs of sodium and chloride ions for every electron transferred through the circuit. With two additional stages (total of 3.8 L of anolyte), desalination was increased to 98% salt removal, producing 0.3 L of fresh water (12.6:1). These results demonstrate that stacked MDCs can be used for efficient desalination of seawater while at the same time achieving power densities comparable to those obtained in MFCs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lovley, D. R., & Phillips, E. J. P. (1988) · Applied and Environmental Microbiology · doi:10.1128/aem.54.6.1472-1480.1988 · Cited by 2,395
Cited by
Emerging desalination technologies for water treatment: A critical review
Subramani, A., & Jacangelo, J. G. (2015) · Water Research · doi:10.1016/j.watres.2015.02.032 · Cited by 959
A comprehensive review of microbial electrochemical systems as a platform technology
Wang, H., & Ren, Z. J. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.10.001 · Cited by 835
Assessment of Microbial Fuel Cell Configurations and Power Densities
Logan, B. E., Wallack, M. J., Kim, K.-Y., He, W., Feng, Y., & Saikaly, P. E. (2015) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.5b00180 · Cited by 517
Self-citationMicrobial desalination cells for energy production and desalination
Kim, Y., & Logan, B. E. (2013) · Desalination · doi:10.1016/j.desal.2012.07.022 · Cited by 287
Self-citationLuo, H., Xu, P., Roane, T. M., Jenkins, P. E., & Ren, Z. (2012) · Bioresource Technology · doi:10.1016/j.biortech.2011.11.098 · Cited by 256
Metadata
- Authors
- Kim, Y., & Logan, B. E.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-06-15
- Volume
- 45
- Issue
- 13
- Pages
- 5840-5845
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2021192381
- Cited by
- 190
- References
- 1
- FWCI
- 15.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Series Assembly of Microbial Desalination Cells Containing Stacked Electrodialysis Cells for Partial or Complete Seawater Desalination. https://app.cochat.ai/papers/10.1021/es200584q
- The paper
- Kim, Y., & Logan, B. E. (2011). Series Assembly of Microbial Desalination Cells Containing Stacked Electrodialysis Cells for Partial or Complete Seawater Desalination. Environmental Science & Technology. https://doi.org/10.1021/es200584q
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.