The DOI matches its Crossref record.
Evidence and Recommendations to Support the Use of a Novel Passive Water Sampler to Quantify Antibiotics in Wastewaters
Abstract
A novel passive water sampler (diffusive gradients in thin-films for organics, o-DGT) was previously developed and successfully tested in the laboratory, but has not yet been validated in the field. Here, o-DGT samplers were deployed in the influent and effluent of a typical UK wastewater treatment plant (WWTP); the influent was also sampled with a conventional automatic sampler (Auto) and by grab (Grab) sampling. All the samples were analyzed by LC-MS/MS for 40 target antibiotics (including 16 sulfonamides (SAs), 12 fluoroquinolones, 6 macrolides, 2 ionophores, 2 diaminopyimidines, 1 aminocoumarin, and 1 lincosamide). The diffusion coefficients (D) of these antibiotics in o-DGT, measured in the laboratory, ranged from 0.58 × 10(-06) to 6.24 × 10(-06) cm(2) s(-1). The derived surface area normalized sampling rates (RS/A, 0.54-5.74 mL d(-1) cm(-2)) were comparable with those for another passive sampler called POCIS. Fourteen antibiotics were detected in the actively sampled water samples, with 10 of the 14 detected in o-DGT devices deployed for more than 7 days. Most of the antibiotics detected in o-DGT, except sulfapyridine, were continually accumulated by o-DGT for ~10 days. Deployment for 7 days is recommended to integrate ambient concentrations over time, without risks of reaching capacity and significant biofouling. Diffusive boundary layer (DBL) thickness had less effect on the o-DGT measurement than reported for other passive samplers. The comparison between o-DGT and Auto and Grab samplings showed that o-DGT was more efficient in terms of cost, time, and labor. This study demonstrates for the first time in a real environment that o-DGT is an effective tool for the routine monitoring of antibiotics in wastewaters and provides a powerful approach to studying their occurrence, fate, and behavior in the environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D., & Kimura, S. Y. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04493 · Cited by 413
Poly- and Perfluorinated Alkyl Substances in Air and Water from Dhaka, Bangladesh
Morales-McDevitt, M. E., Dunn, M., Habib, A., Vojta, S., Becanova, J., & Lohmann, R. (2022) · Environmental Toxicology and Chemistry · doi:10.1002/etc.5255 · Cited by 42
Metadata
- Authors
- Chen, C.-E., Zhang, H., Ying, G.-G., & Jones, K. C.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-11-15
- Volume
- 47
- Issue
- 23
- Pages
- 13587-13593
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2073614075
- Cited by
- 188
- References
- 0
- FWCI
- 6.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evidence and Recommendations to Support the Use of a Novel Passive Water Sampler to Quantify Antibiotics in Wastewaters. https://app.cochat.ai/papers/10.1021/es402662g
- The paper
- Chen, C.-E., Zhang, H., Ying, G.-G., & Jones, K. C. (2013). Evidence and Recommendations to Support the Use of a Novel Passive Water Sampler to Quantify Antibiotics in Wastewaters. Environmental Science & Technology. https://doi.org/10.1021/es402662g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.