Cited by 463Environmental remediation with nanomaterialsAdvanced oxidation water treatmentArsenic contamination and mitigation

pH Dependence of Fenton Reagent Generation and As(III) Oxidation and Removal by Corrosion of Zero Valent Iron in Aerated Water

Katsoyiannis, Ioannis A., Ruettimann, Thomas, Hug, Stephan J.·2008·Environmental Science & Technology

Abstract

Corrosion of zerovalent iron (ZVI) in oxygen-containing water produces reactive intermediates that can oxidize various organic and inorganic compounds. We investigated the kinetics and mechanism of Fenton reagent generation and As(III) oxidation and removal by ZVI (0.1m2/g) from pH 3-11 in aerated water. Observed half-lives for the oxidation of initially 500 microg/L As(III) by 150 mg Fe(0)/L were 26-80 min at pH 3-9. At pH 11, no As(III) oxidation was observed during the first two hours. Dissolved Fe(III) reached 325, 140, and 6 microM at pH 3, 5, and 7. H2O2 concentrations peaked within 10 min at 1.2, 0.4, and < 0.1 microM at pH 3, 5, and 7, and then decreased to undetectable levels. Addition of 2,2'-bipyridine (1-3 mM), prevented Fe(II) oxidation by O2 and H2O2 and inhibited As(III)oxidation. 2-propanol (14 mM), scavenging OH-radicals, quenched the As(III) oxidation at pH 3, but had almost no effect at pH 5 and 7. Experimental data and kinetic modeling suggest that As(III) was oxidized mainly in solution by the Fenton reaction and removed by sorption on newly formed hydrous ferric oxides. OH-radials are the main oxidant for As(III) at low pH, whereas a more selective oxidant oxidizes As(III) at circumneutral pH.

Integrity signals

Registry

Crossref · 10.1021/es800649p

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Ferrihydrite, granular ferric hydroxide, and hydrous ferric oxide are the most widely explored iron oxides and hydroxides for removal of arsenic, yielding promising results for both AsIII and AsV removals.

    “Ferrihydrite, granular ferric hydroxide, and hydrous ferric oxide are the most widely explored iron oxides and hydroxides for the removal of As yielding promising results for both AsIII and AsV removals [174, 180–184].”

Cited by

Sorted by citations

Authors
Katsoyiannis, I. A., Ruettimann, T., & Hug, S. J.
Affiliations
Swiss Federal Institute of Aquatic Science and Technology (CH)
Corresponding author
  • Katsoyiannis, Ioannis A.
  • Hug, Stephan J.
Venue
Environmental Science & Technology
Published
2008-08-30
Volume
42
Issue
19
Pages
7424-7430
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W1975108808
Cited by
463
References
0
Citations by year
2026: 12 · 2025: 27 · 2024: 29 · 2023: 35 · 2022: 38 · 2021: 33 · 2020: 36 · 2019: 37 · 2018: 25 · 2017: 23 · 2016: 33 · 2015: 33 · 2014: 28 · 2013: 18 · 2012: 14
FWCI
9.28
Type
journal article
Language
en
Open access
closed
Locations
  • Environmental Science & Technology (publishedVersion)
  • PubMed (publishedVersion)
  • DORA Eawag (Swiss Federal Institute of Aquatic Science and Technology (Eawag)) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Environmental remediation with nanomaterials
  • Physical Sciences › Environmental Science › Water Science and Technology › Advanced oxidation water treatment
  • Physical Sciences › Environmental Science › Environmental Chemistry › Arsenic contamination and mitigation
Keywords
arsenite oxidation, pH dependence, hydrogen peroxide, hydroxyl radicals, ferrihydrite, 2,2'-bipyridine, kinetic modeling, aerated water, groundwater remediation
MeSH terms
Arsenic, Corrosion, Hydrogen Peroxide, Hydrogen-Ion Concentration, Iron, Kinetics, Oxidation-Reduction, Solubility, Solutions, Water, 2-Propanol

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review