CoChat

Quantification of Carbon Savings from Improved Biomass Cookstove Projects

Johnson, Michael, Edwards, Rufus, Ghilardi, Adrián, Berrueta, Victor, Gillen, Dan, Frenk, Claudio Alatorre, Masera, Omar · 2009 · Environmental Science & Technology
Cited by 106

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In spite of growing interest, a principal obstacle to wider inclusion of improved cookstove projects in carbon trading schemes has been the lack of accountability in estimating CO2-equivalent (CO2-e) savings. To demonstrate that robust estimates of CO2-e savings can be obtained at reasonable cost, an integrated approach of community-based subsampling of traditional and improved stoves in homes to estimate fuel consumption and greenhouse gas emissions, combined with spatially explicit community-based estimates of the fraction of nonrenewable biomass harvesting (fNRB), was used to estimate CO2-e savings for 603 homes with improved Patsari stoves in Purépecha communities of Michoacán, Mexico. Mean annual household CO2-e savings for CO2, CH4, CO, and nonmethane hydrocarbons were 3.9 tCO2-e home(-1) yr(-1) (95% Cl +/- 22%), and for Kyoto gases (CO2 and CH4) were 3.1 tCO2-e home(-1) yr(-1) (95% Cl +/- 26%), respectively, using a weighted mean fNRB harvesting of 39%. CO2-e savings ranged from 1.6 (95% Cl +/- 49%) to 7.5 (95% Cl +/- 17%) tCO2-e home(-1) yr(-1) for renewable and nonrenewable harvesting in individual communities, respectively. Since emission factors, fuel consumption, and fNRB each contribute significantly to the overall uncertainty in estimates of CO2-e savings, community-based assessment of all of these parameters is critical for robust estimates. Reporting overall uncertainty in the CO2-e savings estimates provides a mechanism for valuation of carbon offsets, which would promote better accounting that CO2-e savings had actually been achieved. Cost of CO2-e savings as a result of adoption of Patsari stoves was U.S. $8 per tCO2-e based on initial stove costs, monitoring costs, and conservative stove adoption rates, which is approximately 4 times less expensive than use of carbon capture and storage from coal plants, and approximately 18 times less than solar power. The low relative cost of CO2-e abatement of improved stoves combined with substantial health cobenefits through reduction in indoor air pollution provides a strong rationale for targeting these less expensive carbon mitigation options, while providing substantial economic assistance for stove dissemination efforts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es801564u

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 106

Metadata

Authors
Johnson, M., Edwards, R., Ghilardi, A., Berrueta, V., Gillen, D., Frenk, C. A., & Masera, O.
Venue
Environmental Science & Technology
Published
2009-03-02
Volume
43
Issue
7
Pages
2456-2462
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2303676662
Cited by
106
References
1
FWCI
7.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.