CoChat

Solid-Phase Microextraction of Nitrogen- and Phosphorus-Containing Pesticides from Water and Gas Chromatographic Analysis

Choudhury, Tarun K., Gerhardt, Klaus O., Mawhinney, Thomas P. · 1996 · Environmental Science & Technology
Cited by 84

The DOI matches its Crossref record.

Abstract

Solid-phase microextraction (SPME), a single-step solvent-free extraction, followed by gas−liquid chro matography (GC) employing a nitrogen−phosphorus detector (NPD) and mass spectrometry (MS) was evaluated for the measurement of the 46 nitrogen- and phosphorus-containing pesticides of U.S. EPA Method 507. Effects of pH, ionic strength, methanol content, and temperature on extraction were determined. Analytes were extracted into a bonded polydimethylsiloxane phase coated on a fused-silica fiber and then thermally desorbed in a GC injector and analyzed. Absorption−time and absorption−concentration profiles were obtained for each SPME-extractable pesticide. When analyzed by SPME GC/NPD or by SPME GC/MS, 34 and 39 pesticides, respectively, were measured at levels lower than the EPA method detection limits and precision require ments. This method was applied to the analysis of contaminated well water, watershed, and streamwater and compared to U.S. EPA Method 507 findings. These results demonstrate that SPME is a valuable tool for the rapid screening of 39 EPA Method 507 nitrogen- and phosphorus-containing pesticides in water.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es960040w

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Choudhury, T. K., Gerhardt, K. O., & Mawhinney, T. P.
Venue
Environmental Science & Technology
Published
1996-10-01
Volume
30
Issue
11
Pages
3259-3265
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W1996971521
Cited by
84
References
0
FWCI
8.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.