The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Retrievable and Highly Selective Fluorescent Probe for Monitoring Sulfide and Imaging in Living Cells
Open accessAbstract
A novel selective fluorescent chemosensor based on an 8-hydroxyquinoline-appended fluorescein derivative (L1) was synthesized and characterized. Once combined with Cu(2+), it displayed high specificity for sulfide anion. Among the various anions, only sulfide anion induced the revival of fluoresecence of L1, which was quenched by Cu(2+), resulting in "off-on"-type sensing of sulfide anion. What's more, the sensor was retrievable to indicate sulfide anions with Cu(2+), and S(2-), in turn, increased. With the addition of Cu(2+), compound L1 could give rise to a visible pink-to-yellow color change and green fluorescence quenching. The resulting yellow solution could change to pink and regenerate to green fluorescence immediately upon the addition of sulfide anion; however, no changes were observed in the presence of other anions, including CN(-), P(2)O(7)(4-), and other forms of sulfate, making compound L1 an extremely selective and efficient sulfide chemosensor. The signal transduction occurs via reversible formation-separation of complex L1Cu and CuS. What's more, the biological imaging study has demonstrated that the chemosensor can detect sulfur anions in biological systems at a relatively low concentration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
H 2 S as a Physiologic Vasorelaxant: Hypertension in Mice with Deletion of Cystathionine γ-Lyase
Yang, G., Wu, L., Jiang, B., Yang, W., Qi, J., Cao, K., Meng, Q., Mustafa, A. K., Mu, W., Zhang, S., et al. (2008) · Science · doi:10.1126/science.1162667 · Cited by 2,310
Cited by
Metal coordination in photoluminescent sensing
Liu, Z., He, W., & Guo, Z. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35363f · Cited by 800
Thiol Reactive Probes and Chemosensors
Peng, H., Chen, W., Cheng, Y., Hakuna, L., Strongin, R., & Wang, B. (2012) · Sensors · doi:10.3390/s121115907 · Cited by 275
Fluorescent probes for sensing and imaging biological hydrogen sulfide
Lin, V. S., & Chang, C. J. (2012) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2012.07.014 · Cited by 260
Small Molecule Optical Probes for Detection of H2S in Water Samples: A Review
M, R., Kulkarni, R. M., & Sunil, D. (2024) · ACS Omega · doi:10.1021/acsomega.3c08573 · Cited by 38
Metadata
- Authors
- Hou, F., Huang, L., Xi, P., Cheng, J., Zhao, X., Xie, G., Shi, Y., Cheng, F., Yao, X., Bai, D., & Zeng, Z.
- Venue
- Inorganic Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-02-03
- Volume
- 51
- Issue
- 4
- Pages
- 2454-2460
- ISSN
- 0020-1669 (ISSN-L)
- 1520-510X
- OpenAlex
- W2319512084
- Cited by
- 278
- References
- 1
- FWCI
- 16.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.