The DOI matches its Crossref record; 151 of the 151 references it cites were found in a registry or an index.
Thiol Reactive Probes and Chemosensors
Open accessAbstract
Thiols are important molecules in the environment and in biological processes. Cysteine (Cys), homocysteine (Hcy), glutathione (GSH) and hydrogen sulfide (H2S) play critical roles in a variety of physiological and pathological processes. The selective detection of thiols using reaction-based probes and sensors is very important in basic research and in disease diagnosis. This review focuses on the design of fluorescent and colorimetric probes and sensors for thiol detection. Thiol detection methods include probes and labeling agents based on nucleophilic addition and substitution, Michael addition, disulfide bond or Se-N bond cleavage, metal-sulfur interactions and more. Probes for H2S are based on nucleophilic cyclization, reduction and metal sulfide formation. Thiol probe and chemosensor design strategies and mechanism of action are discussed in this review.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new and rapid colorimetric determination of acetylcholinesterase activity
Ellman, G. L., Courtney, K. D., Andres, V., & Featherstone, R. M. (1961) · Biochemical Pharmacology · doi:10.1016/0006-2952(61)90145-9 · Cited by 27,126
Ellman, G. L. (1959) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(59)90090-6 · Cited by 26,311
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Selenium: Biochemical Role as a Component of Glutathione Peroxidase
Rotruck, J. T., Pope, A. L., Ganther, H. E., Swanson, A. B., Hafeman, D. G., & Hoekstra, W. G. (1973) · Science · doi:10.1126/science.179.4073.588 · Cited by 7,809
Meister, A., & Anderson, M. E. (1983) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.52.070183.003431 · Cited by 5,680
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Glutathione Metabolism and Its Implications for Health
Wu, G., Lupton, J. R., Turner, N. D., Fang, Y.-Z., & Yang, S. (2004) · The Journal of Nutrition · doi:10.1093/jn/134.3.489 · Cited by 3,842
Glutathione: overview of its protective roles, measurement, and biosynthesis
Forman, H. J., Zhang, H., & Rinna, A. (2009) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2008.08.006 · Cited by 2,636
The possible role of hydrogen sulfide as an endogenous neuromodulator
Abe, K., & Kimura, H. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-03-01066.1996 · Cited by 2,239
Metadata
- Authors
- Peng, H., Chen, W., Cheng, Y., Hakuna, L., Strongin, R., & Wang, B.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2012-11-19
- Volume
- 12
- Issue
- 11
- Pages
- 15907-15946
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W1967094458
- Cited by
- 275
- References
- 151
- FWCI
- 10.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thiol Reactive Probes and Chemosensors. https://app.cochat.ai/papers/10.3390/s121115907
- The paper
- Peng, H., Chen, W., Cheng, Y., Hakuna, L., Strongin, R., & Wang, B. (2012). Thiol Reactive Probes and Chemosensors. Sensors. https://doi.org/10.3390/s121115907
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.