The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Cyclometalated Iridium(III) Complexes for Phosphorescence Sensing of Biological Metal Ions
Abstract
Phosphorescence signaling provides a valuable alternative to conventional bioimaging based on fluorescence. The benefits of using phosphorescent molecules include improved sensitivity and capabilities for effective elimination of background signals by time-gated acquisition. Cyclometalated Ir(III) complexes are promising candidates for facilitating phosphorescent bioimaging because they provide synthetic versatility and excellent phosphorescence properties. In this Forum Article, we present our recent studies on the development of phosphorescence sensors for the detection of metal ions based on cyclometalated iridium(III) complexes. The constructs contained cyclometalating (C^N) ligands with the electron densities and band-gap energies of the C^N ligand structures systematically varied. Receptors that chelated zinc, cupric, and chromium ions were tethered to the ligands to create phosphorescence sensors. The alterations in the C^N ligand structures had a profound influence on the phosphorescence responses to metal ions. Mechanistic studies suggested that the phosphorescence responses could be explained on the basis of the modulation of photoinduced electron transfer (PeT) from the receptor to the photoexcited iridium species. The PeT behaviors strictly adhered to the Rehm-Weller principle, and the occurrence of PeT was located in the Marcus-normal region. It is thus anticipated that improved responses will be obtainable by increasing the excited-state reduction potential of the iridium(III) complexes. Femtosecond transient absorption experiments provided evidence for the presence of an additional photophysical mechanism that involved metal-ion-induced alteration of the intraligand charge-transfer (ILCT) transition state. Utility of the mechanism by PeT and ILCT has been demonstrated for the phosphorescence sensing of biologically important transition-metal ions. In particular, the phosphorescence zinc sensor could report the presence of intracellular zinc pools by using confocal laser scanning microscopy and photoluminescence lifetime imaging microscopy techniques. We hope that the significant knowledge gained from our studies will be of great help in the design of new molecules as phosphorescence sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Small-Molecule Fluorescent Sensors for Investigating Zinc Metalloneurochemistry
Nolan, E. M., & Lippard, S. J. (2009) · Accounts of Chemical Research · doi:10.1021/ar8001409 · Cited by 620
Imaging mobile zinc in biology
Tomat, E., & Lippard, S. J. (2010) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2009.12.010 · Cited by 217
Cited by
He, L., Li, Y., Tan, C.-P., Ye, R.-R., Chen, M.-H., Cao, J.-J., Ji, L.-N., & Mao, Z.-W. (2015) · Chemical Science · doi:10.1039/c5sc01955a · Cited by 358
de Souza, B., Farias, G., Neese, F., & Izsák, R. (2019) · Journal of Chemical Theory and Computation · doi:10.1021/acs.jctc.8b00841 · Cited by 323
Metadata
- Authors
- You, Y., Cho, S., & Nam, W.
- Venue
- Inorganic Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-11-22
- Volume
- 53
- Issue
- 4
- Pages
- 1804-1815
- ISSN
- 0020-1669 (ISSN-L)
- 1520-510X
- OpenAlex
- W2118408940
- Cited by
- 159
- References
- 2
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cyclometalated Iridium(III) Complexes for Phosphorescence Sensing of Biological Metal Ions. https://app.cochat.ai/papers/10.1021/ic4013872
- The paper
- You, Y., Cho, S., & Nam, W. (2014). Cyclometalated Iridium(III) Complexes for Phosphorescence Sensing of Biological Metal Ions. Inorganic Chemistry. https://doi.org/10.1021/ic4013872
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.