The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Reconstruction-Based Fault Identification Using a Combined Index
Abstract
Process monitoring and fault diagnosis are crucial for efficient and optimal operation of a chemical plant. This paper proposes a reconstruction-based fault identification approach using a combined index for multidimensional fault reconstruction and identification. Fault detection is conducted using a new index that combines the squared prediction error (SPE) and T 2 . Necessary and sufficient conditions for fault detectability are derived. The combined index is used to reconstruct the fault along a given fault direction. Faults are identified by assuming that each fault in a candidate fault set is the true fault and comparing the reconstructed indices with the control limits. Fault reconstructability and identifiability on the basis of the combined index are discussed. A new method to extract fault directions from historical fault data is proposed. The dimension of the fault is determined on the basis of the fault detection indices after fault reconstruction. Several simulation examples and one practical case are presented. The method proposed here is compared with two existing methods in the literature for the identification single-sensor and multiple-sensor faults. We analyze the reasons that the other two methods lead to erroneous identification results. Finally, the proposed approach is applied to a rapid thermal annealing process for fault diagnosis. Fault subspaces of several typical process faults are extracted from the data and then used to identify new faults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multivariate SPC Charts for Monitoring Batch Processes
Nomikos, P., & MacGregor, J. F. (1995) · Technometrics · doi:10.1080/00401706.1995.10485888 · Cited by 1,422
Multivariate statistical monitoring of process operating performance
Kresta, J. V., Macgregor, J. F., & Marlin, T. E. (1991) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450690105 · Cited by 989
The process chemometrics approach to process monitoring and fault detection
Wise, B. M., & Gallagher, N. B. (1996) · Journal of Process Control · doi:10.1016/0959-1524(96)00009-1 · Cited by 852
Proceedings of the 1995 American Control Conference
(1995) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.1995.529194 · Cited by 589
Identification of faulty sensors using principal component analysis
Dunia, R., Qin, S. J., Edgar, T. F., & McAvoy, T. J. (1996) · AIChE Journal · doi:10.1002/aic.690421011 · Cited by 526
Self-citationGeneralized contribution plots in multivariate statistical process monitoring
Westerhuis, J. A., Gurden, S. P., & Smilde, A. K. (2000) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(00)00062-9 · Cited by 507
Subspace approach to multidimensional fault identification and reconstruction
Dunia, R. H., & Qin, S. J. (1998) · AIChE Journal · doi:10.1002/aic.690440812 · Cited by 382
Self-citationJoint diagnosis of process and sensor faults using principal component analysis
Dunia, R., & Joe Qin, S. (1998) · Control Engineering Practice · doi:10.1016/s0967-0661(98)00027-6 · Cited by 251
Ziegel, E., & Krishnaiah, P. R. (1986) · Technometrics · doi:10.2307/1268998 · Cited by 248
Improved Process Understanding Using Multiway Principal Component Analysis
Kosanovich, K. A., Dahl, K. S., & Piovoso, M. J. (1996) · Industrial & Engineering Chemistry Research · doi:10.1021/ie9502594 · Cited by 217
Detection of gross erros in data reconciliation by principal component analysis
Tong, H., & Crowe, C. M. (1995) · AIChE Journal · doi:10.1002/aic.690410711 · Cited by 175
Cited by
Statistical process monitoring: basics and beyond
Joe Qin, S. (2003) · Journal of Chemometrics · doi:10.1002/cem.800 · Cited by 1,582
Survey on data-driven industrial process monitoring and diagnosis
Qin, S. J. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.004 · Cited by 1,470
Self-citationReview of Recent Research on Data-Based Process Monitoring
Ge, Z., Song, Z., & Gao, F. (2013) · Industrial & Engineering Chemistry Research · doi:10.1021/ie302069q · Cited by 967
Reconstruction-based contribution for process monitoring
Alcala, C. F., & Qin, S. J. (2009) · Automatica · doi:10.1016/j.automatica.2009.02.027 · Cited by 567
Self-citationFault detection and identification of nonlinear processes based on kernel PCA
Choi, S. W., Lee, C., Lee, J.-M., Park, J. H., & Lee, I.-B. (2005) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2004.05.001 · Cited by 454
Metadata
- Authors
- Yue, H. H., & Qin, S. J.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-08-30
- Volume
- 40
- Issue
- 20
- Pages
- 4403-4414
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W1978677160
- Cited by
- 509
- References
- 11
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.