The DOI matches its Crossref record.
Pilot Plant Studies of the CO2 Capture Performance of Aqueous MEA and Mixed MEA/MDEA Solvents at the University of Regina CO2 Capture Technology Development Plant and the Boundary Dam CO2 Capture Demonstration Plant
Abstract
Evaluations of the benefits of using a mixed MEA/MDEA solvent for CO 2 capture in terms of the heat requirement for solvent regeneration, lean and rich loadings, CO 2 production, and solvent stability were performed by comparing the performance of aqueous 5 kmol/m 3 MEA with that of an aqueous 4:1 molar ratio MEA/MDEA blend of 5 kmol/m 3 total amine concentration as a function of the operating time. The tests were performed using two pilot CO 2 capture plants of the International Test Centre for CO 2 Capture (ITC), which provided two different sources and compositions of flue gas. The University of Regina CO 2 plant (UR unit) processes flue gas from the combustion of natural gas while the Boundary Dam CO 2 plant (BD unit) processes flue gas from a coal-fired electric power station. The results show that a huge heat-duty reduction can be achieved by using a mixed MEA/MDEA solution instead of a single MEA solution in an industrial environment of a CO 2 capture plant. However, this benefit is dependent on whether the chemical stability of the solvent can be maintained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carbon capture and storage (CCS): the way forward
Bui, M., Adjiman, C. S., Bardow, A., Anthony, E. J., Boston, A., Brown, S., Fennell, P. S., Fuss, S., Galindo, A., Hackett, L. A., et al. (2018) · Energy & Environmental Science · doi:10.1039/c7ee02342a · Cited by 4,374
CO2 capture and separation technologies for end-of-pipe applications – A review
Olajire, A. A. (2010) · Energy · doi:10.1016/j.energy.2010.02.030 · Cited by 1,217
Natural gas origin, composition, and processing: A review
Faramawy, S., Zaki, T., & Sakr, A. A.-E. (2016) · Journal of Natural Gas Science and Engineering · doi:10.1016/j.jngse.2016.06.030 · Cited by 788
Calcium looping sorbents for CO2 capture
Erans, M., Manovic, V., & Anthony, E. J. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.07.074 · Cited by 369
Carbon Capture Technologies: A Review on Technology Readiness Level
Hekmatmehr, H., Esmaeili, A., Pourmahdi, M., Atashrouz, S., Abedi, A., Ali Abuswer, M., Nedeljkovic, D., Latifi, M., Farag, S., & Mohaddespour, A. (2024) · Fuel · doi:10.1016/j.fuel.2024.130898 · Cited by 189
Metadata
- Authors
- Idem, R., Wilson, M., Tontiwachwuthikul, P., Chakma, A., Veawab, A., Aroonwilas, A., & Gelowitz, D.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-08-06
- Volume
- 45
- Issue
- 8
- Pages
- 2414-2420
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2029369504
- Cited by
- 587
- References
- 0
- FWCI
- 10.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pilot Plant Studies of the CO2 Capture Performance of Aqueous MEA and Mixed MEA/MDEA Solvents at the University of Regina CO2 Capture Technology Development Plant and the Boundary Dam CO2 Capture Demonstration Plant. https://app.cochat.ai/papers/10.1021/ie050569e
- The paper
- Idem, R., Wilson, M., Tontiwachwuthikul, P., Chakma, A., Veawab, A., Aroonwilas, A., & Gelowitz, D. (2006). Pilot Plant Studies of the CO2 Capture Performance of Aqueous MEA and Mixed MEA/MDEA Solvents at the University of Regina CO2 Capture Technology Development Plant and the Boundary Dam CO2 Capture Demonstration Plant. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie050569e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.