Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 257

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Experimental Measurement of the Solubility and Diffusivity of CO2 in Room-Temperature Ionic Liquids Using a Transient Thin-Liquid-Film Method

Hou, Ying, Baltus, Ruth E.·2007·Industrial & Engineering Chemistry Research

Abstract

In this paper, results from an experimental investigation of carbon dioxide (CO 2 ) solubility and diffusivity in the ionic liquids 1- n -butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([bmim][Tf 2 N]), 1,2-dimethyl-3-propylimidazolium bis(trifluoromethylsulfonyl)imide ([pmmim][Tf 2 N]), 1-butyl-3-methylpyridinium bis(trifluoromethyl sulfonyl)imide ([bmpy][Tf 2 N]), 1-(3,4,5,6-perfluorohexyl)-3-methylimdazolium bis(trifluoromethyl sulfonyl)imide ([perfluoro-hmim][Tf 2 N]), and 1- n -butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF 4 ]) are reported. A transient thin liquid film method was developed, which enables one to determine the Henry's law constant and the diffusivity at low pressure simultaneously. Measurements were performed at temperatures in the range of 283 − 323 K. Henry's law constants were in the range of 25.5−84 bar and were in general agreement with measurements reported by other researchers for these and similar ionic liquids. The entropies and enthalpies of absorption were determined to increase as gas solubility decreased. The measured CO 2 diffusion coefficients in the five ionic liquids were ∼10 -6 cm 2 /s, which is an order of magnitude smaller than the coefficients for CO 2 diffusion in traditional organic solvents. In contrast to the gas solubility results, measured diffusion coefficients were determined to be dependent on the ionic liquid cation as well as the anion. In addition, CO 2 diffusion coefficients were considerably more sensitive to temperature than were CO 2 solubilities in these ionic liquids. Results were used to develop a correlation relating CO 2 diffusion to ionic liquid properties and system temperature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ie070501u

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 257

Metadata

Authors
Hou, Y., & Baltus, R. E.
Venue
Industrial & Engineering Chemistry Research
Published
2007-10-18
Volume
46
Issue
24
Pages
8166-8175
ISSN
  • 0888-5885 (ISSN-L)
  • 1520-5045
OpenAlex
W2004620717
Cited by
257
References
26
FWCI
4.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental Measurement of the Solubility and Diffusivity of CO2 in Room-Temperature Ionic Liquids Using a Transient Thin-Liquid-Film Method. https://app.cochat.ai/papers/10.1021/ie070501u
The paper
Hou, Y., & Baltus, R. E. (2007). Experimental Measurement of the Solubility and Diffusivity of CO2 in Room-Temperature Ionic Liquids Using a Transient Thin-Liquid-Film Method. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie070501u

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.