Experimental Measurement of the Solubility and Diffusivity of CO2 in Room-Temperature Ionic Liquids Using a Transient Thin-Liquid-Film Method
Abstract
In this paper, results from an experimental investigation of carbon dioxide (CO 2 ) solubility and diffusivity in the ionic liquids 1- n -butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([bmim][Tf 2 N]), 1,2-dimethyl-3-propylimidazolium bis(trifluoromethylsulfonyl)imide ([pmmim][Tf 2 N]), 1-butyl-3-methylpyridinium bis(trifluoromethyl sulfonyl)imide ([bmpy][Tf 2 N]), 1-(3,4,5,6-perfluorohexyl)-3-methylimdazolium bis(trifluoromethyl sulfonyl)imide ([perfluoro-hmim][Tf 2 N]), and 1- n -butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF 4 ]) are reported. A transient thin liquid film method was developed, which enables one to determine the Henry's law constant and the diffusivity at low pressure simultaneously. Measurements were performed at temperatures in the range of 283 − 323 K. Henry's law constants were in the range of 25.5−84 bar and were in general agreement with measurements reported by other researchers for these and similar ionic liquids. The entropies and enthalpies of absorption were determined to increase as gas solubility decreased. The measured CO 2 diffusion coefficients in the five ionic liquids were ∼10 -6 cm 2 /s, which is an order of magnitude smaller than the coefficients for CO 2 diffusion in traditional organic solvents. In contrast to the gas solubility results, measured diffusion coefficients were determined to be dependent on the ionic liquid cation as well as the anion. In addition, CO 2 diffusion coefficients were considerably more sensitive to temperature than were CO 2 solubilities in these ionic liquids. Results were used to develop a correlation relating CO 2 diffusion to ionic liquid properties and system temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The properties of gases and liquids
(2001) · Choice Reviews Online · doi:10.5860/choice.38-5036 · Cited by 12,958
Hydrophobic, Highly Conductive Ambient-Temperature Molten Salts
Bonhôte, P., Dias, A.-P., Papageorgiou, N., Kalyanasundaram, K., & Grätzel, M. (1996) · Inorganic Chemistry · doi:10.1021/ic951325x · Cited by 4,358
Ionic liquids. Green solvents for the future
Earle, M. J., & Seddon, K. R. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072071391 · Cited by 2,811
Influence of chloride, water, and organic solvents on the physical properties of ionic liquids
Seddon, K. R., Stark, A., & Torres, M.-J. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072122275 · Cited by 2,293
A short history of ionic liquids—from molten salts to neoteric solvents
Wilkes, J. S. (2002) · Green Chemistry · doi:10.1039/b110838g · Cited by 1,684
Thermophysical Properties of Imidazolium-Based Ionic Liquids
Fredlake, C. P., Crosthwaite, J. M., Hert, D. G., Aki, S. N. V. K., & Brennecke, J. F. (2004) · Journal of Chemical & Engineering Data · doi:10.1021/je034261a · Cited by 1,553
Why Is CO2 So Soluble in Imidazolium-Based Ionic Liquids?
Cadena, C., Anthony, J. L., Shah, J. K., Morrow, T. I., Brennecke, J. F., & Maginn, E. J. (2004) · Journal of the American Chemical Society · doi:10.1021/ja039615x · Cited by 1,518
Ionic liquids: Innovative fluids for chemical processing
Brennecke, J. F., & Maginn, E. J. (2001) · AIChE Journal · doi:10.1002/aic.690471102 · Cited by 1,432
Ackermann, T. (1973) · Zeitschrift für Physikalische Chemie · doi:10.1524/zpch.1973.84.1-4.224 · Cited by 1,197
Anion Effects on Gas Solubility in Ionic Liquids
Anthony, J. L., Anderson, J. L., Maginn, E. J., & Brennecke, J. F. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp046404l · Cited by 1,058
Cited by
Carbon capture and storage update
Boot-Handford, M. E., Abanades, J. C., Anthony, E. J., Blunt, M. J., Brandani, S., Mac Dowell, N., Fernández, J. R., Ferrari, M.-C., Gross, R., Hallett, J. P., et al. (2014) · Energy Environ. Sci. · doi:10.1039/c3ee42350f · Cited by 2,386
A Review of CO2 Capture by Absorption and Adsorption
Yu, C.-H., Huang, C.-H., & Tan, C.-S. (2012) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.05.0132 · Cited by 1,730
An overview of CO2 capture technologies
MacDowell, N., Florin, N., Buchard, A., Hallett, J., Galindo, A., Jackson, G., Adjiman, C. S., Williams, C. K., Shah, N., & Fennell, P. (2010) · Energy & Environmental Science · doi:10.1039/c004106h · Cited by 1,636
State-of-the-Art of CO2Capture with Ionic Liquids
Ramdin, M., de Loos, T. W., & Vlugt, T. J. H. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie3003705 · Cited by 1,073
Gas Solubility in Ionic Liquids
Lei, Z., Dai, C., & Chen, B. (2014) · Chemical Reviews · doi:10.1021/cr300497a · Cited by 1,038
Metadata
- Authors
- Hou, Y., & Baltus, R. E.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-10-18
- Volume
- 46
- Issue
- 24
- Pages
- 8166-8175
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2004620717
- Cited by
- 257
- References
- 26
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental Measurement of the Solubility and Diffusivity of CO2 in Room-Temperature Ionic Liquids Using a Transient Thin-Liquid-Film Method. https://app.cochat.ai/papers/10.1021/ie070501u
- The paper
- Hou, Y., & Baltus, R. E. (2007). Experimental Measurement of the Solubility and Diffusivity of CO2 in Room-Temperature Ionic Liquids Using a Transient Thin-Liquid-Film Method. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie070501u
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.