The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Selective Extraction of Copper, Mercury, Silver, and Palladium Ions from Water Using Hydrophobic Ionic Liquids
Abstract
Extraction of dilute metal ions from water was performed near room temperature with a variety of ionic liquids. Distribution coefficients are reported for fourteen metal ions extracted with ionic liquids containing cations 1-octyl-4-methylpyridinium [4MOPYR]{sup +}, 1-methyl-1-octylpyrrolidinium [MOPYRRO]{sup +} or 1-methyl-1-octylpiperidinium [MOPIP]{sup +}, and anions tetrafluoroborate [BF{sub 4}]{sup +}, trifluoromethyl sulfonate [TfO]{sup +} or nonafluorobutyl sulfonate [NfO]{sup +}. Ionic liquids containing octylpyridinium cations are very good for extracting mercury ions. However, other metal ions were not significantly extracted by any of these ionic liquids. Extractions were also performed with four new task-specific ionic liquids. Such liquids containing a disulfide functional group are efficient and selective for mercury and copper, whereas those containing a nitrile functional group are efficient and selective for silver and palladium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cases of mercury exposure, bioavailability, and absorption
Gochfeld, M. (2003) · Ecotoxicology and Environmental Safety · doi:10.1016/s0147-6513(03)00060-5 · Cited by 485
Cited by
Environmental Application, Fate, Effects, and Concerns of Ionic Liquids: A Review
Amde, M., Liu, J.-F., & Pang, L. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b03123 · Cited by 491
Processing of metals and metal oxides using ionic liquids
Abbott, A. P., Frisch, G., Hartley, J., & Ryder, K. S. (2011) · Green Chemistry · doi:10.1039/c0gc00716a · Cited by 404
Patel, D. D., & Lee, J. (2012) · The Chemical Record · doi:10.1002/tcr.201100036 · Cited by 308
Self-citationHalometallate ionic liquids – revisited
Estager, J., Holbrey, J. D., & Swadźba-Kwaśny, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60310e · Cited by 308
Billard, I., Ouadi, A., & Gaillard, C. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4478-x · Cited by 274
Metadata
- Authors
- Papaiconomou, N., Lee, J.-M., Salminen, J., von Stosch, M., & Prausnitz, J. M.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-09-12
- Volume
- 47
- Issue
- 15
- Pages
- 5080-5086
- ISSN
- 0888-5885
- 1520-5045
- OpenAlex
- W1995187928
- Cited by
- 167
- References
- 1
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective Extraction of Copper, Mercury, Silver, and Palladium Ions from Water Using Hydrophobic Ionic Liquids. https://app.cochat.ai/papers/10.1021/ie0706562
- The paper
- Papaiconomou, N., Lee, J.-M., Salminen, J., von Stosch, M., & Prausnitz, J. M. (2008). Selective Extraction of Copper, Mercury, Silver, and Palladium Ions from Water Using Hydrophobic Ionic Liquids. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie0706562
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.