Complexation Hydrogels for the Oral Delivery of Growth Hormone and Salmon Calcitonin
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The hydrogel system of poly(methacrylic acid-co-N-vinyl pyrrolidone) was evaluated for use as an oral delivery system for growth hormone and salmon calcitonin. These proteins were selected because of their therapeutic importance and the insight provided by evaluating the delivery of a therapeutic agent with a high molecular weight (growth hormone) and a drug with a high isoelectric point (salmon calcitonin). Growth hormone loading and release studies were performed for both P(MAA-co-NVP) and P(MAA-g-PEG). Loading efficiencies for the respective systems were 50.9 ± 1.8% and 57.8 ± 4.1%; weight incorporation of the protein was determined to be 3.5 ± 0.1% and 4.0 ± 0.3%. At pH 7.4, growth hormone release of 90% occurred within 45 min for P(MAA-co-NVP) microparticles; 90% release was not achieved with P(MAA-g-PEG) microparticles until 180 min. At pH 1.2, no release occurred from P(MAA-co-NVP) microparticles but 10% release occurred from P(MAA-g-PEG) microparticles. Salmon calcitonin loading and release were shown to be affected by the negative charges of deprotonated MAA; for systems with monomer molar feed ratios of 4:1, 1:1 and 1:4 MAA:NVP, loading efficiencies were determined to be 70.6 ± 3.0%, 25.3 ± 1.2%, and 1.6 ± 1.3%. Salmon calcitonin release was minimal from the copolymer with 4:1 MAA:NVP monomer feed at pH 7.4. The release improved when the pH was raised above physiological levels. These studies confirmed that P(MAA-co-NVP) was an effective oral delivery system for high molecular weight drugs, but improvements are needed before the system could be utilized for high isoelectric point therapeutic delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evidence for Calcitonin—A New Hormone from the Parathyroid That Lowers Blood Calcium
COPP, D. H., CAMERON, E. C., CHENEY, B. A., DAVIDSON, A. G. F., & HENZE, K. G. (1962) · Endocrinology · doi:10.1210/endo-70-5-638 · Cited by 697
Cited by
Stimulus-responsive hydrogels: theory, modern advances, and applications
Koetting, M. C., Peters, J. T., Steichen, S. D., & Peppas, N. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2015.04.001 · Cited by 1,191
Self-citationpH-Responsive carriers for oral drug delivery: Challenges and opportunities of current platforms
Liu, L., Yao, W., Rao, Y., Lu, X., & Gao, J. (2017) · Drug Delivery · doi:10.1080/10717544.2017.1279238 · Cited by 420
“P(MAA-g-EG)) in the small intestine, leading to binding rather than release for absorption into the blood (Carr et al., 2010).”
BackgroundTherapeutic applications of hydrogels in oral drug delivery
Sharpe, L. A., Daily, A. M., Horava, S. D., & Peppas, N. A. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.902047 · Cited by 354
“Other proteins evaluated for oral delivery include salmon calcitonin, a model analog for human calcitonin -- a hormone treatment for postmenopausal osteoporosis [36,38] and growth hormone for treating diseases associated with stunted development and decelerated growth [36].”
BackgroundSelf-citationBiomedical applications of hydrogels in drug delivery system: An update
Kesharwani, P., Bisht, A., Alexander, A., Dave, V., & Sharma, S. (2021) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2021.102914 · Cited by 288
Metadata
- Authors
- Carr, D. A., Gómez-Burgaz, M., Boudes, M. C., & Peppas, N. A.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-09-29
- Volume
- 49
- Issue
- 23
- Pages
- 11991-11995
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2039470057
- Cited by
- 38
- References
- 1
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.