The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Iodine Confinement into Metal–Organic Frameworks (MOFs): Low-Temperature Sintering Glasses To Form Novel Glass Composite Material (GCM) Alternative Waste Forms
Abstract
The safe handling of reprocessed fuel addresses several scientific goals, especially when considering the capture and long-term storage of volatile radionuclides that are necessary during this process. Despite not being a major component of the off-gas, radioiodine (I 2 ) is particularly challenging, because it is a highly mobile gas and 129 I is a long-lived radionuclide (1.57 × 10 7 years). Therefore, its capture and sequestration is of great interest on a societal level. Herein, we explore novel routes toward the effective capture and storage of iodine. In particular, we report on the novel use of a new class of porous solid-state functional materials (metal–organic frameworks, MOFs), as high-capacity adsorbents of molecular iodine. We further describe the formation of novel glass-composite material (GCM) waste forms from the mixing and sintering of the I 2 -containing MOFs with Bi–Zn–O low-temperature sintering glasses and silver metal flakes. Our findings indicate that, upon sintering, a uniform monolith is formed, with no evidence of iodine loss; iodine is sequestered during the heating process by the in situ formation of AgI. Detailed materials characterization analysis is presented for the GCMs. This includes powder X-ray diffraction, scanning electron microscopy coupled with energy-dispersive spectroscopy (SEM-EDS), thermal analysis (thermogravimetric analysis (TGA)), and chemical durability tests including aqueous leach studies (product consistency test (PCT)), with X-ray fluorescence (XRF) and inductively coupled plasma–mass spectrometry (ICP-MS) of the PCT leachate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal-organic framework materials as catalysts
Lee, J., Farha, O. K., Roberts, J., Scheidt, K. A., Nguyen, S. T., & Hupp, J. T. (2009) · Chemical Society Reviews · doi:10.1039/b807080f · Cited by 7,969
Cited by
Capture of Volatile Iodine, a Gaseous Fission Product, by Zeolitic Imidazolate Framework-8
Sava, D. F., Rodriguez, M. A., Chapman, K. W., Chupas, P. J., Greathouse, J. A., Crozier, P. S., & Nenoff, T. M. (2011) · Journal of the American Chemical Society · doi:10.1021/ja204757x · Cited by 725
Self-citationSensing and capture of toxic and hazardous gases and vapors by metal–organic frameworks
Wang, H., Lustig, W. P., & Li, J. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00885f · Cited by 695
Destruction of Metal–Organic Frameworks: Positive and Negative Aspects of Stability and Lability
Feng, L., Wang, K.-Y., Day, G. S., Ryder, M. R., & Zhou, H.-C. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00722 · Cited by 662
Iodine capture in porous organic polymers and metal–organic frameworks materials
Xie, W., Cui, D., Zhang, S.-R., Xu, Y.-H., & Jiang, D.-L. (2019) · Materials Horizons · doi:10.1039/c8mh01656a · Cited by 622
Highly porous and stable metal–organic frameworks for uranium extraction
Carboni, M., Abney, C. W., Liu, S., & Lin, W. (2013) · Chemical Science · doi:10.1039/c3sc50230a · Cited by 598
Metadata
- Authors
- Sava, D. F., Garino, T. J., & Nenoff, T. M.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-05-24
- Volume
- 51
- Issue
- 2
- Pages
- 614-620
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2085663062
- Cited by
- 182
- References
- 1
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.