Onsite CO2 Capture from Flue Gas by an Adsorption Process in a Coal-Fired Power Plant
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The feasibility and efficiency of adsorption technology were evaluated experimentally and theoretically for CO 2 capture from the flue gas in an existing coal-fired power plant, where a three-bed VPSA unit was set up to test 282 kg of adsorbent materials. In this work, the experimental results are reported for zeolite 5A as the adsorbent. The composition of the flue gas after dehydration was 15.0 vol % CO 2, 76.5 vol % N 2, and 8.5 vol % O 2 . With a three-bed seven-step VPSA process including rinse and pressure equalization steps, 85% CO 2 was obtained with recovery of 79% from flue gas at a feed flow rate of 46.0 Nm 3 /h. The experimentally measured energy consumption was 2.37 MJ/(kg of CO 2 ). The experimental work was compared with numerical simulations through the multibed VPSA modeling framework developed in a previous work. The simulated results were found to agree well with the experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reducing the Cost of CO 2 Capture from Flue Gases Using Pressure Swing Adsorption
Ho, M. T., Allinson, G. W., & Wiley, D. E. (2008) · Industrial & Engineering Chemistry Research · doi:10.1021/ie070831e · Cited by 566
Cited by
A Review of CO2 Capture by Absorption and Adsorption
Yu, C.-H., Huang, C.-H., & Tan, C.-S. (2012) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.05.0132 · Cited by 1,730
“…et al. , 1995; Ho et al. , 2008; Li et al. , 2008; Dasgupta et al. , 2009; Zhang et al. , 2009a; Dasgupta et al. , 2012; Grande et al. , 2012; Krishna and Long, 2012; Krishna and van Baten, 2012; Krishna, 2012; Liu et al. , 2012; Lopes et al. , 2012; Rezaei and Webley, 2012; Ribeiro et al. , 2012).”
InfluentialAdsorption of Carbon Dioxide for post-combustion capture: a review
Raganati, F., Miccio, F., & Ammendola, P. (2021) · Energy & Fuels · doi:10.1021/acs.energyfuels.1c01618 · Cited by 661
Research progress on CO2 capture and utilization technology
Fu, L., Ren, Z., Si, W., Ma, Q., Huang, W., Liao, K., Huang, Z., Wang, Y., Li, J., & Xu, P. (2022) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2022.102260 · Cited by 529
Advancements in CO2 capture by absorption and adsorption: A comprehensive review
Soo, X. Y. D., Lee, J. J. C., Wu, W.-Y., Tao, L., Wang, C., Zhu, Q., & Bu, J. (2024) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2024.102727 · Cited by 509
Abanades, J. C., Arias, B., Lyngfelt, A., Mattisson, T., Wiley, D. E., Li, H., Ho, M. T., Mangano, E., & Brandani, S. (2015) · International Journal of Greenhouse Gas Control · doi:10.1016/j.ijggc.2015.04.018 · Cited by 441
CO2 capture from dry flue gas by vacuum swing adsorption: A pilot plant study
Krishnamurthy, S., Rao, V. R., Guntuka, S., Sharratt, P., Haghpanah, R., Rajendran, A., Amanullah, M., Karimi, I. A., & Farooq, S. (2014) · AIChE Journal · doi:10.1002/aic.14435 · Cited by 282
CO 2 capture from humid flue gases and humid atmosphere using a microporous coppersilicate
Datta, S. J., Khumnoon, C., Lee, Z. H., Moon, W. K., Docao, S., Nguyen, T. H., Hwang, I. C., Moon, D., Oleynikov, P., Terasaki, O., et al. (2015) · Science · doi:10.1126/science.aab1680 · Cited by 282
Sustainable biomass-based carbon adsorbents for post-combustion CO2 capture
González, A. S., Plaza, M. G., Rubiera, F., & Pevida, C. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.06.118 · Cited by 280
Review on Reactor Configurations for Adsorption-Based CO 2 Capture
Dhoke, C., Zaabout, A., Cloete, S., & Amini, S. (2021) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.0c04547 · Cited by 240
Plaza, M. G., & Rubiera, F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.05.079 · Cited by 53
Green coffee based CO2 adsorbent with high performance in postcombustion conditions
Plaza, M. G., González, A. S., Pevida, C., & Rubiera, F. (2015) · Fuel · doi:10.1016/j.fuel.2014.10.014 · Cited by 47
Influence of Water Vapor on CO2 Adsorption Using a Biomass-Based Carbon
Plaza, M. G., González, A. S., Pevida, C., & Rubiera, F. (2014) · Industrial & Engineering Chemistry Research · doi:10.1021/ie500342q · Cited by 41
Strategies for CO2 capture from different CO2 emission sources by vacuum swing adsorption technology
Ling, J., Xiao, P., Ntiamoah, A., Xu, D., Webley, P., & Zhai, Y. (2016) · Chinese Journal of Chemical Engineering · doi:10.1016/j.cjche.2015.11.030 · Cited by 21
Performance-Based Screening of Porous Materials for Carbon Capture
Farmahini, A. H., Krishnamurthy, S., Friedrich, D., Brandani, S., & Sarkisov, L. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01266 · Cited by 7
Metadata
- Authors
- Liu, Z., Wang, L., Kong, X., Li, P., Yu, J., & Rodrigues, A. E.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-05-15
- Volume
- 51
- Issue
- 21
- Pages
- 7355-7363
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2322193747
- Cited by
- 126
- References
- 1
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.