CoChat

Simulation and Optimization of a Dual-Adsorbent, Two-Bed Vacuum Swing Adsorption Process for CO2 Capture from Wet Flue Gas

Krishnamurthy, Shreenath, Haghpanah, Reza, Rajendran, Arvind, Farooq, Shamsuzzaman · 2014 · Industrial & Engineering Chemistry Research
Cited by 61

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Various options for the capture and concentration of CO 2 from a wet flue gas at 25 °C containing 15% CO 2 in 82% N 2 and 3% moisture have been analyzed through detailed simulation and optimization. First, a proven cycle for dry flue gas, consisting of four steps including light product pressurization in a column packed with zeolite 13X established in an earlier communication ( Haghpanah et al. AIChE J. 2013, 59, 4735) and demonstrated at the pilot scale ( Krishnamurthy et al. AIChE J. 2014, 60, 1830), was applied to the wet flue gas. Detailed optimization studies using a nondominated sorting genetic algorithm (NSGA-II) in MATLAB were carried out first to maximize purity and recovery. Further optimization was carried out to obtain the operating conditions corresponding to minimum energy consumption subject to 95% purity and 90% recovery constraints. The minimum energy consumption in this process required to achieve 95% purity (dry basis) and 90% recovery was 230 kWh (t of CO 2 captured) −1 with a productivity of 1.03 t of CO 2 (m 3 of 13X) −1 day –1 . This energy consumption was considerably higher and the productivity was considerably lower than those reported for dry flue gas ( Haghpanah et al. AIChE J. 2013, 59, 4735). Next, to improve the performance, a new dual-adsorbent, four-step vacuum swing adsorption (VSA) process with silica gel and zeolite 13X packed separately in two beds was proposed. By separating the two adsorbents in two beds, instead of layering them in the same column, it was possible to avoid rewetting of the concentrated CO 2 . The process optimization of the new cycle revealed that the 95% purity and 90% recovery target could be achieved at a lower energy penalty [177 kWh (t of CO 2 captured) −1 ] while also improving the productivity [1.82 t of CO 2 (m 3 of 13X) −1 day –1, 1.29 t of CO 2 (m 3 of total adsorbent) −1 day –1 ].

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ie5024723

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 61

Metadata

Authors
Krishnamurthy, S., Haghpanah, R., Rajendran, A., & Farooq, S.
Venue
Industrial & Engineering Chemistry Research
Published
2014-09-04
Volume
53
Issue
37
Pages
14462-14473
ISSN
  • 0888-5885 (ISSN-L)
  • 1520-5045
OpenAlex
W2317102511
Cited by
61
References
2
FWCI
2.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simulation and Optimization of a Dual-Adsorbent, Two-Bed Vacuum Swing Adsorption Process for CO2 Capture from Wet Flue Gas. https://app.cochat.ai/papers/10.1021/ie5024723
The paper
Krishnamurthy, S., Haghpanah, R., Rajendran, A., & Farooq, S. (2014). Simulation and Optimization of a Dual-Adsorbent, Two-Bed Vacuum Swing Adsorption Process for CO2 Capture from Wet Flue Gas. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie5024723

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.