CoChat

Effect of Temperature in Fluidized Bed Fast Pyrolysis of Biomass: Oil Quality Assessment in Test Units

Open access
Westerhof, Roel J. M., Brilman, Derk W. F. (Wim), van Swaaij, Wim P. M., Kersten, Sacha R. A. · 2010 · Industrial & Engineering Chemistry Research
Cited by 147

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Pine wood was pyrolyzed in a 1 kg/h fluidized bed fast pyrolysis reactor that allows a residence time of pine wood particles up to 25 min. The reactor temperature was varied between 330 and 580 °C to study the effect on product yields and oil composition. Apart from the physical−chemical analysis, a pyrolysis oil quality assessment has been performed by using two applications. The pyrolysis oils were tested in a laboratory scale atomizer and in a hydrodeoxygenation unit for upgrading/stabilizing of the pyrolysis oil. The pyrolysis oil yield increases from 330 to 450 °C, is nearly constant between 450 and 530 °C, and decreases again at a pyrolysis temperature of 580 °C. At temperatures of 360 and 580 °C, total pyrolysis oil yields of, respectively, 58 and 56 dry wt % can still be obtained. The produced amount of water is already significant at a reactor temperature of 360 °C and becomes constant at a temperature of 400 °C. At a temperature of 580 °C, the water production starts to decrease slightly. Initially the number average molecular weight of the pyrolysis oil increases at increasing temperatures, which is ascribed to the observed increase in concentration of water insoluble compound in the pyrolysis oil. At a temperature of 580 °C, the number average molecular weight, viscosity, and the amount of produced water insoluble compounds decreases. The oil obtained at a pyrolysis temperature of 360 °C produced less char, 2 versus 5 wt %, compared to the oil obtained at a pyrolysis temperature of 530 °C in our atomizer/gasifier. About 100% of the carbon goes to the gas phase compared to 84% for the oil obtained at a pyrolysis temperature of 530 °C. Therefore, the 360 °C oil has a better quality for this unit under the applied conditions (850 °C and droplet sizes of 50± μm) Testing the three pyrolysis oils (pyrolysis temperatures of 330, 530, and 580 °C) in the hydrodeoxygenation unit showed that pyrolysis oil with a lower viscosity resulted in deoxygenated oil of lower viscosity. The oxygen content of the three oils was almost the same, but the yield of the deoxygenated oils obtained at a pyrolysis temperature of 330 °C was significantly lower. Together with chemical and physical analyzes of the pyrolysis oils, feeding the pyrolysis oil into a test units relevant for applications, direct information on the effect of varied pyrolysis process parameters on the quality and applicability of the pyrolysis oil is obtained.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ie900885c

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Westerhof, R. J. M., Brilman, D. W. F. (., van Swaaij, W. P. M., & Kersten, S. R. A.
Venue
Industrial & Engineering Chemistry Research
Published
2010-02-03
Volume
49
Issue
3
Pages
1160-1168
ISSN
  • 0888-5885 (ISSN-L)
  • 1520-5045
OpenAlex
W2072646830
Cited by
147
References
2
FWCI
6.21
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.