The DOI matches its Crossref record.
Colloidal Au-Enhanced Surface Plasmon Resonance for Ultrasensitive Detection of DNA Hybridization
Abstract
A new approach to ultrasensitive detection of DNA hybridization based on nanoparticle-amplified surface plasmon resonance (SPR) is described. Use of the Au nanoparticle tags leads to a greater than 10-fold increase in angle shift, corresponding to a more than 1000-fold improvement in sensitivity for the target oligonucleotide as compared to the unamplified binding event. This enhanced shift in SPR reflectivity is a combined result of greatly increased surface mass, high dielectric constant of Au particles, and electromagnetic coupling between Au nanoparticles and the Au film. DNA melting and digestion experiments further supported the feasibility of this approach in DNA hybridization studies. The extremely large angle shifts observed in particle-amplified SPR make it possible to conduct SPR imaging experiments on DNA arrays. In the present work, macroscopic 4 × 4 arrays were employed, and a ∼10 pM limit of quantitation was achieved for 24-mer oligonucleotides (surface density ≤8 × 10 8 molecules/cm 2 ). Even without further optimization, the sensitivity of this technique begins to approach that of traditional fluorescence-based methods for DNA hybridization. These results illustrate the potential of particle-amplified SPR for array-based DNA analysis and ultrasensitive detection of oligonucleotides.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Surface-Enhanced Raman Spectroscopy
Haynes, C. L., McFarland, A. D., & Van Duyne, R. P. (2005) · Analytical Chemistry · doi:10.1021/ac053456d · Cited by 1,144
Ray, P. C. (2010) · Chemical Reviews · doi:10.1021/cr900335q · Cited by 773
Xu, W., Xue, X., Li, T., Zeng, H., & Liu, X. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901772 · Cited by 382
Polymer Mediated Self-Assembly of Magnetic Nanoparticles
Sun, S., Anders, S., Hamann, H. F., Thiele, J.-U., Baglin, J. E. E., Thomson, T., Fullerton, E. E., Murray, C. B., & Terris, B. D. (2002) · Journal of the American Chemical Society · doi:10.1021/ja0176503 · Cited by 301
Metadata
- Authors
- He, L., Musick, M. D., Nicewarner, S. R., Salinas, F. G., Benkovic, S. J., Natan, M. J., & Keating, C. D.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-09-01
- Volume
- 122
- Issue
- 38
- Pages
- 9071-9077
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2048702576
- Cited by
- 932
- References
- 0
- FWCI
- 17.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Colloidal Au-Enhanced Surface Plasmon Resonance for Ultrasensitive Detection of DNA Hybridization. https://app.cochat.ai/papers/10.1021/ja001215b
- The paper
- He, L., Musick, M. D., Nicewarner, S. R., Salinas, F. G., Benkovic, S. J., Natan, M. J., & Keating, C. D. (2000). Colloidal Au-Enhanced Surface Plasmon Resonance for Ultrasensitive Detection of DNA Hybridization. Journal of the American Chemical Society. https://doi.org/10.1021/ja001215b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.