The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fluorescent Sensors for Zn2+Based on a Fluorescein Platform: Synthesis, Properties and Intracellular Distribution
Open accessAbstract
Two new fluorescent sensors for Zn(2+) that utilize fluorescein as a reporting group, Zinpyr-1 and Zinpyr-2, have been synthesized and characterized. Zinpyr-1 is prepared in one step via a Mannich reaction, and Zinpyr-2 is obtained in a multistep synthesis that utilizes 4',5'-fluorescein dicarboxaldehyde as a key intermediate. Both Zinpyr sensors have excitation and emission wavelengths in the visible range ( approximately 500 nm), dissociation constants (K(d1)) for Zn(2+) of <1 nM, quantum yields approaching unity (Phi = approximately 0.9), and cell permeability, making them well-suited for intracellular applications. A 3- to 5-fold fluorescent enhancement is observed under simulated physiological conditions corresponding to the binding of the Zn(2+) cation to the sensor, which inhibits a photoinduced electron transfer (PET) quenching pathway. The X-ray crystal structure of a 2:1 Zn(2+):Zinpyr-1 complex has also been solved, and is the first structurally characterized example of a complex of fluorescein substituted with metal binding ligands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal ions and synaptic transmission: think zinc
Huang, E. P. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.25.13386 · Cited by 160
Cited by
Gunnlaugsson, T., Glynn, M., Tocci (née Hussey), G. M., Kruger, P. E., & Pfeffer, F. M. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.08.017 · Cited by 1,257
Calixarene‐Derived Fluorescent Probes
Kim, J. S., & Quang, D. T. (2007) · ChemInform · doi:10.1002/chin.200749272 · Cited by 1,052
Zinc transporters and the cellular trafficking of zinc
Eide, D. J. (2006) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2006.03.005 · Cited by 874
Small-Molecule Fluorescent Sensors for Investigating Zinc Metalloneurochemistry
Nolan, E. M., & Lippard, S. J. (2009) · Accounts of Chemical Research · doi:10.1021/ar8001409 · Cited by 620
Self-citationZinc sensing for cellular application
Kikuchi, K., Komatsu, K., & Nagano, T. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.02.007 · Cited by 320
Metadata
- Authors
- Burdette, S. C., Walkup, G. K., Spingler, B., Tsien, R. Y., & Lippard, S. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-07-24
- Volume
- 123
- Issue
- 32
- Pages
- 7831-7841
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2007891562
- Cited by
- 744
- References
- 1
- FWCI
- 14.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescent Sensors for Zn2+Based on a Fluorescein Platform: Synthesis, Properties and Intracellular Distribution. https://app.cochat.ai/papers/10.1021/ja010059l
- The paper
- Burdette, S. C., Walkup, G. K., Spingler, B., Tsien, R. Y., & Lippard, S. J. (2001). Fluorescent Sensors for Zn2+Based on a Fluorescein Platform: Synthesis, Properties and Intracellular Distribution. Journal of the American Chemical Society. https://doi.org/10.1021/ja010059l
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.