The DOI matches its Crossref record.
Electroosmotic Flow in Template-Prepared Carbon Nanotube Membranes
Abstract
Carbon nanotube membranes (CNMs) were prepared by doing chemical vapor deposition of carbon within the pores of a microporous alumina template. Electroosmotic flow (EOF) was driven across the CNMs by allowing the membrane to separate two electrolyte solutions and using an electrode in each solution to pass a constant ionic current through the nanotubes. EOF was investigated by measuring the flux of a probe molecule (phenol) across the CNM. The as-synthesized CNMs have anionic surface charge, and EOF is in the direction of cation migration across the membrane. Measurements of the rate of EOF as a function of applied transmembrane current provided the zeta potential. The effect of pH on zeta provided the pK(a) for the surface acidic sites responsible for this anionic charge; the acidic-site density was also determined. An electrochemical derivatization method was used to attach carboxylate groups to the nanotube walls; this enhances the anionic surface charge density, resulting in a corresponding increase in the EOF rate. Electrochemical derivatization was also used to attach cationic ammonium sites to the nanotube walls to yield CNMs that show EOF in the opposite direction of the as-synthesized or carboxylated membranes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Synthesis of a large-scale highly ordered porous carbon film by self-assembly of block copolymers
Liang, C., Hong, K., Guiochon, G. A., Mays, J. W., & Dai, S. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200461051 · Cited by 834
Complex plasmas: An interdisciplinary research field
Morfill, G. E., & Ivlev, A. V. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1353 · Cited by 803
Smart Nanotubes for Bioseparations and Biocatalysis
Mitchell, D. T., Lee, S. B., Trofin, L., Li, N., Nevanen, T. K., Söderlund, H., & Martin, C. R. (2002) · Journal of the American Chemical Society · doi:10.1021/ja027247b · Cited by 549
Self-citationAltalhi, T., Kumeria, T., Santos, A., & Losic, D. (2013) · Carbon · doi:10.1016/j.carbon.2013.07.003 · Cited by 39
Metadata
- Authors
- Miller, S. A., Young, V. Y., & Martin, C. R.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-11-10
- Volume
- 123
- Issue
- 49
- Pages
- 12335-12342
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2037424153
- Cited by
- 239
- References
- 0
- FWCI
- 7.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electroosmotic Flow in Template-Prepared Carbon Nanotube Membranes. https://app.cochat.ai/papers/10.1021/ja011926p
- The paper
- Miller, S. A., Young, V. Y., & Martin, C. R. (2001). Electroosmotic Flow in Template-Prepared Carbon Nanotube Membranes. Journal of the American Chemical Society. https://doi.org/10.1021/ja011926p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.