The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Formation of Polymer Vesicles or “Peptosomes” by Polybutadiene-block-poly(l-glutamate)s in Dilute Aqueous Solution
Abstract
Polybutadiene-block-poly(L-glutamate) copolymers were made by anionic polymerization and subsequent ring-opening polymerization of N-carboxyanhydrides and were characterized by NMR, IR, SEC, and circular dichroism. These polymers, when appropriately designed, form so-called "polymersomes" or "peptosomes", vesicles composed of modified protein units. The size and structure of the vesicles are determined by dynamic light scattering, small-angle neutron scattering, and freeze-fracture electron microscopy. It is also shown that the size of the peptosomes does not depend on the pH; that is, the solvating peptide units can perform a helix-coil transition without serious changes of the vesicle morphology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prediction of protein conformation
Chou, P. Y., & Fasman, G. D. (1974) · Biochemistry · doi:10.1021/bi00699a002 · Cited by 3,309
Cited by
Blanazs, A., Armes, S. P., & Ryan, A. J. (2009) · Macromolecular Rapid Communications · doi:10.1002/marc.200800713 · Cited by 1,500
Stimuli-Responsive Polymersomes for Programmed Drug Delivery
Meng, F., Zhong, Z., & Feijen, J. (2009) · Biomacromolecules · doi:10.1021/bm801127d · Cited by 1,122
Discher, D. E., & Ahmed, F. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095838 · Cited by 844
Self-porating polymersomes of peg–pla and peg–pcl: Hydrolysis-triggered controlled release vesicles
Ahmed, F., & Discher, D. E. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2003.12.021 · Cited by 667
Advances and challenges in smart and functional polymer vesicles
Du, J., & O'Reilly, R. K. (2009) · Soft Matter · doi:10.1039/b905635a · Cited by 572
Block copolymer vesicles—using concepts from polymer chemistry to mimic biomembranes
Kita-Tokarczyk, K., Grumelard, J., Haefele, T., & Meier, W. (2005) · Polymer · doi:10.1016/j.polymer.2005.02.083 · Cited by 517
Polymersomes: nature inspired nanometer sized compartments
LoPresti, C., Lomas, H., Massignani, M., Smart, T., & Battaglia, G. (2009) · Journal of Materials Chemistry · doi:10.1039/b818869f · Cited by 416
Hazer, B., & Steinbüchel, A. (2007) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0732-8 · Cited by 405
van Dongen, S. F. M., de Hoog, H.-P. M., Peters, R. J. R. W., Nallani, M., Nolte, R. J. M., & van Hest, J. C. M. (2009) · Chemical Reviews · doi:10.1021/cr900072y · Cited by 386
Stimuli‐Sensitive Synthetic Polypeptide‐Based Materials for Drug and Gene Delivery
He, C., Zhuang, X., Tang, Z., Tian, H., & Chen, X. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201100008 · Cited by 337
Lipid-based nanovesicles for nanomedicine
Grimaldi, N., Andrade, F., Segovia, N., Ferrer-Tasies, L., Sala, S., Veciana, J., & Ventosa, N. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00409a · Cited by 309
Polysaccharide‐block‐polypeptide Copolymer Vesicles: Towards Synthetic Viral Capsids
Schatz, C., Louguet, S., Le Meins, J., & Lecommandoux, S. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200805895 · Cited by 287
A review of polypeptide-based polymersomes
Zhao, L., Li, N., Wang, K., Shi, C., Zhang, L., & Luan, Y. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.10.063 · Cited by 149
Metadata
- Authors
- Kukula, H., Schlaad, H., Antonietti, M., & Förster, S.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-02-01
- Volume
- 124
- Issue
- 8
- Pages
- 1658-1663
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2094483740
- Cited by
- 410
- References
- 1
- FWCI
- 16.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.