The DOI matches its Crossref record.
A Fluorescent Anion Sensor That Works in Neutral Aqueous Solution for Bioanalytical Application
Abstract
Anion recognition and anion sensing are of interest because anions play many important roles in living organisms. Most currently known anion sensors work only in organic solution, but sensors for biological applications are required to function in neutral aqueous solution. We have designed and synthesized a novel fluorescent sensor for anions. The sensor molecule 1-Cd(II) contains 7-amino-4-trifluoromethylcoumarin as a fluorescent reporter and Cd(II)-cyclen (1,4,7,10-tetraazacyclododecane) as an anion host. In neutral aqueous solution, Cd(II) of 1-Cd(II) is coordinated by the four nitrogen atoms of cyclen and the aromatic amino group of coumarin. When various anions are added to 100 mM HEPES buffer solution (pH 7.4) containing 1-Cd(II), the aromatic amino group of coumarin is displaced from Cd(II), causing a change of the excitation spectrum. While pyrophosphate and citrate were detected with high sensitivity, fluoride and perchlorate produced no response. Among organic anions, ATP and ADP gave strong signals, while cAMP showed little signal. By utilizing the different affinities of the sensor for AMP and cAMP, the activity of phosphodiesterase, which cleaves cyclic nucleotide, was monitored in real-time. The sensor should have many biochemical and analytical applications and the sensing principle should be widely applicable to the sensing of other molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorogenic and Chromogenic Chemosensors and Reagents for Anions
Martínez-Máñez, R., & Sancenón, F. (2003) · Chemical Reviews · doi:10.1021/cr010421e · Cited by 3,076
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Fluorescent Dyes and Their Supramolecular Host/Guest Complexes with Macrocycles in Aqueous Solution
Dsouza, R. N., Pischel, U., & Nau, W. M. (2011) · Chemical Reviews · doi:10.1021/cr200213s · Cited by 1,117
Recognition and sensing of fluoride anion
Cametti, M., & Rissanen, K. (2009) · Chemical Communications · doi:10.1039/b902069a · Cited by 654
Artificial Receptors for the Recognition of Phosphorylated Molecules
Hargrove, A. E., Nieto, S., Zhang, T., Sessler, J. L., & Anslyn, E. V. (2011) · Chemical Reviews · doi:10.1021/cr100242s · Cited by 649
Chemosensors for Pyrophosphate
Kim, S. K., Lee, D. H., Hong, J.-I., & Yoon, J. (2009) · Accounts of Chemical Research · doi:10.1021/ar800003f · Cited by 647
Anion coordination and anion-templated assembly: Highlights from 2002 to 2004
Gale, P. A., & Quesada, R. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.05.020 · Cited by 406
Sensing and analysis of soluble phosphates in environmental samples: A review
Warwick, C., Guerreiro, A., & Soares, A. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.012 · Cited by 272
Fluorescent probes for the detection of disease-associated biomarkers
Dou, W.-T., Han, H.-H., Sedgwick, A. C., Zhu, G.-B., Zang, Y., Yang, X.-R., Yoon, J., James, T. D., Li, J., & He, X.-P. (2022) · Science Bulletin · doi:10.1016/j.scib.2022.01.014 · Cited by 266
Sakamoto, T., Ojida, A., & Hamachi, I. (2009) · Chem. Commun. · doi:10.1039/b812374h · Cited by 260
Metadata
- Authors
- Mizukami, S., Nagano, T., Urano, Y., Odani, A., & Kikuchi, K.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-03-21
- Volume
- 124
- Issue
- 15
- Pages
- 3920-3925
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2058075394
- Cited by
- 371
- References
- 0
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.