The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Luminescence Lifetime-Based Sensor for Cyanide and Related Anions
Abstract
A new Ru(II) complex is described which serves as a luminescence lifetime-based sensor for fluoride and cyanide anions (KF = 640 000 mol-1, KCN = 430 000 mol-1). This chromophore displays observable changes in its UV-vis and steady-state luminescence spectra upon cyanide binding. Prior to cyanide addition, this complex exhibits a single-exponential lifetime (tau = 377 +/- 20 ns). With increasing cyanide concentrations, the intensity decays are composed of two exponentials: long tau (320-370 ns) and short tau (13-17 ns). The average lifetimes shorten as a function of cyanide concentration since the fractional intensity shifts from an initial dominant long lifetime component to the short lifetime component. This work represents the first example of a direct method for the luminescence lifetime-based sensing of anions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ru(II) polypyridine complexes: photophysics, photochemistry, eletrochemistry, and chemiluminescence
Juris, A., Balzani, V., Barigelletti, F., Campagna, S., Belser, P., & von Zelewsky, A. (1988) · Coordination Chemistry Reviews · doi:10.1016/0010-8545(88)80032-8 · Cited by 4,862
Cited by
Fluorogenic and Chromogenic Chemosensors and Reagents for Anions
Martínez-Máñez, R., & Sancenón, F. (2003) · Chemical Reviews · doi:10.1021/cr010421e · Cited by 3,076
Phosphorescent chemosensors based on heavy-metal complexes
Zhao, Q., Li, F., & Huang, C. (2010) · Chemical Society Reviews · doi:10.1039/b915340c · Cited by 1,249
Sensors for the optical detection ofcyanide ion
Xu, Z., Chen, X., Kim, H. N., & Yoon, J. (2010) · Chem. Soc. Rev. · doi:10.1039/b907368j · Cited by 1,121
Modern reaction-based indicator systems
Cho, D.-G., & Sessler, J. L. (2009) · Chemical Society Reviews · doi:10.1039/b804436h · Cited by 421
Anion coordination and anion-templated assembly: Highlights from 2002 to 2004
Gale, P. A., & Quesada, R. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.05.020 · Cited by 406
Type I photodynamic therapy by organic–inorganic hybrid materials: From strategies to applications
Wang, Y.-Y., Liu, Y.-C., Sun, H., & Guo, D.-S. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2019.05.016 · Cited by 344
Ekmekci, Z., Yilmaz, M. D., & Akkaya, E. U. (2008) · Organic Letters · doi:10.1021/ol702823u · Cited by 302
Zeng, Q., Cai, P., Li, Z., Qin, J., & Tang, B. Z. (2008) · Chemical Communications · doi:10.1039/b717764j · Cited by 297
Ho, H. A., & Leclerc, M. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028765p · Cited by 295
Johnson, R. M., & Fraser, C. L. (2004) · Biomacromolecules · doi:10.1021/bm034421v · Cited by 46
Metadata
- Authors
- Anzenbacher, Tyson, D. S., Jursíková, K., & Castellano, F. N.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-05-03
- Volume
- 124
- Issue
- 22
- Pages
- 6232-6233
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1964624770
- Cited by
- 460
- References
- 1
- FWCI
- 6.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.