The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Mesoporous Silica Nanosphere-Based Carrier System with Chemically Removable CdS Nanoparticle Caps for Stimuli-Responsive Controlled Release of Neurotransmitters and Drug Molecules
Abstract
An MCM-41 type mesoporous silica nanosphere-based (MSN) controlled-release delivery system has been synthesized and characterized using surface-derivatized cadmium sulfide (CdS) nanocrystals as chemically removable caps to encapsulate several pharmaceutical drug molecules and neurotransmitters inside the organically functionalized MSN mesoporous framework. We studied the stimuli-responsive release profiles of vancomycin- and adenosine triphosphate (ATP)-loaded MSN delivery systems by using disulfide bond-reducing molecules, such as dithiothreitol (DTT) and mercaptoethanol (ME), as release triggers. The biocompatibility and delivery efficiency of the MSN system with neuroglial cells (astrocytes) in vitro were demonstrated. In contrast to many current delivery systems, the molecules of interest were encapsulated inside the porous framework of the MSN not by adsorption or sol-gel types of entrapment but by capping the openings of the mesoporous channels with size-defined CdS nanoparticles to physically block the drugs/neurotransmitters of certain sizes from leaching out. We envision that this new MSN system could play a significant role in developing new generations of site-selective, controlled-release delivery nanodevices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polymeric systems for controlled drug release
Uhrich, K. E., Cannizzaro, S. M., Langer, R. S., & Shakesheff, K. M. (1999) · Chemical Reviews · doi:10.1021/cr940351u · Cited by 2,633
Cited by
Items 101–106 of 106
Cauda, V., Engelke, H., Sauer, A., Arcizet, D., Rädler, J., & Bein, T. (2010) · Nano Letters · doi:10.1021/nl100991w · Cited by 155
Palanikumar, L., Choi, E. S., Cheon, J. Y., Joo, S. H., & Ryu, J. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201402755 · Cited by 150
Mesostructured Silica for Optical Functionality, Nanomachines, and Drug Delivery
Klichko, Y., Liong, M., Choi, E., Angelos, S., Nel, A. E., Stoddart, J. F., Tamanoi, F., & Zink, J. I. (2009) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2008.02722.x · Cited by 116
Cisplatin and doxorubicin dual-loaded mesoporous silica nanoparticles for controlled drug delivery
Li, H., Yu, H., Zhu, C., Hu, J., Du, M., Zhang, F., & Yang, D. (2016) · RSC Advances · doi:10.1039/c6ra17213j · Cited by 57
A hyperbranched amphiphilic acetal polymer for pH-sensitive drug delivery
Cao, H., Chen, C., Xie, D., Chen, X., Wang, P., Wang, Y., Song, H., & Wang, W. (2018) · Polymer Chemistry · doi:10.1039/c7py01739a · Cited by 50
Protamine-Capped Mesoporous Silica Nanoparticles for Biologically Triggered Drug Release
Radhakrishnan, K., Gupta, S., Gnanadhas, D. P., Ramamurthy, P. C., Chakravortty, D., & Raichur, A. M. (2014) · Particle & Particle Systems Characterization · doi:10.1002/ppsc.201300219 · Cited by 50
Metadata
- Authors
- Lai, C.-Y., Trewyn, B. G., Jeftinija, D. M., Jeftinija, K., Xu, S., Jeftinija, S., & Lin, V. S.-Y.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-03-20
- Volume
- 125
- Issue
- 15
- Pages
- 4451-4459
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2004602103
- Cited by
- 1,678
- References
- 1
- FWCI
- 19.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.