The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Coupling Selectivity with Sensitivity in an Integrated Chemosensor Framework: Design of a Hg2+-Responsive Probe, Operating above 500 nm
Abstract
For the highly selective and sensitive sensing of Hg2+ in water, a new design concept was realized where the selectivity of the probe's binding site is amplified by electronic properties of the chromophore. The molecular architecture of this phenoxazinone-type sensor molecule combines two potential coordination sites via an amino-keto conjugative backbone. These structural prerequisites allow only the most preferred mercuric ion to bind to the dithia dioxa monoaza crown unit, while other heavy, transition, and main group metal ions as well as protons are trapped at the keto group, inducing opposite spectral effects due to interaction with either the donor (Hg2+) or the acceptor group (other cations) of the probe. Besides these advantageous features, the probe operates well within the visible range of the spectrum and displays rather intense molar absorptivities as well as fluorescence quantum yields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nile red as a polarity-sensitive fluorescent probe of hydrophobic protein surfaces
Sackett, D. L., & Wolff, J. (1987) · Analytical Biochemistry · doi:10.1016/0003-2697(87)90157-6 · Cited by 591
Cited by
Highly Selective Oligonucleotide‐Based Sensor for Mercury(II) in Aqueous Solutions
Ono, A., & Togashi, H. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200454172 · Cited by 1,162
Luminescent sensors and switches in the early 21st century
Callan, J. F., de Silva, A. P., & Magri, D. C. (2005) · Tetrahedron · doi:10.1016/j.tet.2005.05.043 · Cited by 1,123
Screening Mercury Levels in Fish with a Selective Fluorescent Chemosensor
Yoon, S., Albers, A. E., Wong, A. P., & Chang, C. J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0557987 · Cited by 503
Ros‐Lis, J. V., Marcos, M. D., Mártinez‐Máñez, R., Rurack, K., & Soto, J. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500583 · Cited by 355
Self-citation
Metadata
- Authors
- Descalzo, A. B., Martínez-Máñez, R., Radeglia, R., Rurack, K., & Soto, J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-02-27
- Volume
- 125
- Issue
- 12
- Pages
- 3418-3419
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1971518546
- Cited by
- 309
- References
- 1
- FWCI
- 9.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coupling Selectivity with Sensitivity in an Integrated Chemosensor Framework: Design of a Hg2+-Responsive Probe, Operating above 500 nm. https://app.cochat.ai/papers/10.1021/ja0290779
- The paper
- Descalzo, A. B., Martínez-Máñez, R., Radeglia, R., Rurack, K., & Soto, J. (2003). Coupling Selectivity with Sensitivity in an Integrated Chemosensor Framework: Design of a Hg2+-Responsive Probe, Operating above 500 nm. Journal of the American Chemical Society. https://doi.org/10.1021/ja0290779
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.