The DOI matches its Crossref record.
Ionic Liquids by Proton Transfer: Vapor Pressure, Conductivity, and the Relevance of Δp Ka from Aqueous Solutions
Abstract
We describe the behavior of the conductivity, viscosity, and vapor pressure of various binary liquid systems in which proton transfer occurs between neat Brönsted acids and bases to form salts with melting points below ambient. Such liquids form an important subgroup of the ionic liquid (IL) class of reaction media and electrolytes on which so much attention is currently being focused. Such "protic ionic liquids" exhibit a wide range of thermal stabilities. We find a simple relation between the limit set by boiling, when the total vapor pressure reaches one atm, and the difference in pK(a) value for the acid and base determined in dilute aqueous solutions. For DeltapK(a) values above 10, the boiling point elevation becomes so high (>300 degrees C) that preemptive decomposition prevents its measurement. The completeness of proton transfer in such cases is suggested by the molten salt-like values of the Walden product, which is used to distinguish good from poor ionic liquids. For the good ionic liquids, the hydrogen bonding of acid molecules to the proton-transfer anion is strong enough that boiling points, but not melting points, may maximize at the hydrogen-bonded dianion composition. High boiling liquids of this type constitute an interesting class of high-temperature protonic acid that may have high-temperature fuel cell applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ionic liquids and catalysis: Recent progress from knowledge to applications
Olivier-Bourbigou, H., Magna, L., & Morvan, D. (2010) · Applied Catalysis A: General · doi:10.1016/j.apcata.2009.10.008 · Cited by 1,639
Ionic liquids: solvent properties and organic reactivity
Chiappe, C., & Pieraccini, D. (2005) · Journal of Physical Organic Chemistry · doi:10.1002/poc.863 · Cited by 1,169
Hydrogen bonding in ionic liquids
Hunt, P. A., Ashworth, C. R., & Matthews, R. P. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00278d · Cited by 836
Application of ionic liquids to the electrodeposition of metals
Abbott, A. P., & McKenzie, K. J. (2006) · Physical Chemistry Chemical Physics · doi:10.1039/b607329h · Cited by 817
Multiscale Studies on Ionic Liquids
Dong, K., Liu, X., Dong, H., Zhang, X., & Zhang, S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00776 · Cited by 773
Metadata
- Authors
- Yoshizawa, M., Xu, W., & Angell, C. A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-11-21
- Volume
- 125
- Issue
- 50
- Pages
- 15411-15419
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1979125578
- Cited by
- 946
- References
- 0
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ionic Liquids by Proton Transfer: Vapor Pressure, Conductivity, and the Relevance of Δp Ka from Aqueous Solutions. https://app.cochat.ai/papers/10.1021/ja035783d
- The paper
- Yoshizawa, M., Xu, W., & Angell, C. A. (2003). Ionic Liquids by Proton Transfer: Vapor Pressure, Conductivity, and the Relevance of Δp Ka from Aqueous Solutions. Journal of the American Chemical Society. https://doi.org/10.1021/ja035783d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.