The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
A General Photonic Crystal Sensing Motif: Creatinine in Bodily Fluids
Abstract
We developed a new sensing motif for the detection and quantification of creatinine, which is an important small molecule marker of renal dysfunction. This novel sensor motif is based on our intelligent polymerized crystalline colloidal array (IPCCA) materials, in which a three-dimensional crystalline colloidal array (CCA) of monodisperse, highly charged polystyrene latex particles are polymerized within lightly cross-linked polyacrylamide hydrogels. These composite hydrogels are photonic crystals in which the embedded CCA diffracts visible light and appears intensely colored. Volume phase transitions of the hydrogel cause changes in the CCA lattice spacings which change the diffracted wavelength of light. We functionalized the hydrogel with two coupled recognition modules, a creatinine deiminase (CD) enzyme and a 2-nitrophenol (2NPh) titrating group. Creatinine within the gel is rapidly hydrolyzed by the CD enzyme in a reaction which releases OH(-). This elevates the steady-state pH within the hydrogel as compared to the exterior solution. In response, the 2NPh is deprotonated. The increased solubility of the phenolate species as compared to that of the neutral phenols causes a hydrogel swelling which red-shifts the IPCCA diffraction. This photonic crystal IPCCA senses physiologically relevant creatinine levels, with a detection limit of 6 microM, at physiological pH and salinity. This sensor also determines physiological levels of creatinine in human blood serum samples. This sensing technology platform is quite general. It may be used to fabricate photonic crystal sensors for any species for which there exists an enzyme which catalyzes it to release H(+) or OH(-).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of polymer chemistry
Oster, G. (1954) · Journal of Chemical Education · doi:10.1021/ed031p669.2 · Cited by 2,503
Polymerized colloidal crystal hydrogel films as intelligent chemical sensing materials
Holtz, J. H., & Asher, S. A. (1997) · Nature · doi:10.1038/39834 · Cited by 2,004
Self-citationPhotonic Crystal Carbohydrate Sensors: Low Ionic Strength Sugar Sensing
Asher, S. A., Alexeev, V. L., Goponenko, A. V., Sharma, A. C., Lednev, I. K., Wilcox, C. S., & Finegold, D. N. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021037h · Cited by 488
Self-citationHigh Ionic Strength Glucose-Sensing Photonic Crystal
Alexeev, V. L., Sharma, A. C., Goponenko, A. V., Das, S., Lednev, I. K., Wilcox, C. S., Finegold, D. N., & Asher, S. A. (2003) · Analytical Chemistry · doi:10.1021/ac030021m · Cited by 405
Self-citationReese, C. E., Guerrero, C. D., Weissman, J. M., Lee, K., & Asher, S. A. (2000) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2000.7190 · Cited by 222
Self-citationSolvent-assisted proton transfer in catalysis by zeolite solid acids
Haw, J. F., Xu, T., Nicholas, J. B., & Goguen, P. W. (1997) · Nature · doi:10.1038/39843 · Cited by 179
Photonic Crystal Aqueous Metal Cation Sensing Materials
Asher, S. A., Sharma, A. C., Goponenko, A. V., & Ward, M. M. (2003) · Analytical Chemistry · doi:10.1021/ac026328n · Cited by 161
Self-citationMădăraş, M. B., & Buck, R. P. (1996) · Analytical Chemistry · doi:10.1021/ac960239r · Cited by 129
Microfabricated amperometric creatine and creatinine biosensors
Mădăraş, M. B., Popescu, I., Ufer, S., & Buck, R. P. (1996) · Analytica Chimica Acta · doi:10.1016/0003-2670(95)00508-0 · Cited by 96
Creatinine sensitive biosensor based on ISFETs and creatinine deiminase immobilised in BSA membrane
Soldatkin, A. P. (2002) · Talanta · doi:10.1016/s0039-9140(02)00283-7 · Cited by 83
Cited by
Synthetic Molecular Motors and Mechanical Machines
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200504313 · Cited by 2,609
Erbas-Cakmak, S., Leigh, D. A., McTernan, C. T., & Nussbaumer, A. L. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00146 · Cited by 1,982
Ge, J., & Yin, Y. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.200907091 · Cited by 1,168
Photonic Crystals for Chemical Sensing and Biosensing
Fenzl, C., Hirsch, T., & Wolfbeis, O. S. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201307828 · Cited by 884
Colloidal Assembly: The Road from Particles to Colloidal Molecules and Crystals
Li, F., Josephson, D. P., & Stein, A. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201001451 · Cited by 737
Self‐Assembled Photonic Structures
Galisteo‐López, J. F., Ibisate, M., Sapienza, R., Froufe‐Pérez, L. S., Blanco, Á., & López, C. (2011) · Advanced Materials · doi:10.1002/adma.201000356 · Cited by 668
Synthetische molekulare Motoren und mechanische Maschinen
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie · doi:10.1002/ange.200504313 · Cited by 624
Tunable Colors in Opals and Inverse Opal Photonic Crystals
Aguirre, C. I., Reguera, E., & Stein, A. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201000143 · Cited by 603
Patterned Colloidal Photonic Crystals
Hou, J., Li, M., & Song, Y. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201704752 · Cited by 510
Photonic crystals: emerging biosensors and their promise for point-of-care applications
Inan, H., Poyraz, M., Inci, F., Lifson, M. A., Baday, M., Cunningham, B. T., & Demirci, U. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00206d · Cited by 480
Colloidal Self-Assembly Approaches to Smart Nanostructured Materials
Li, Z., Fan, Q., & Yin, Y. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00482 · Cited by 468
Self-assembled colloidal structures for photonics
Kim, S.-H., Lee, S. Y., Yang, S.-M., & Yi, G.-R. (2011) · NPG Asia Materials · doi:10.1038/asiamat.2010.192 · Cited by 422
Colorful humidity sensitive photonic crystal hydrogel
Tian, E., Wang, J., Zheng, Y., Song, Y., Jiang, L., & Zhu, D. (2008) · Journal of Materials Chemistry · doi:10.1039/b717368g · Cited by 344
A colloidoscope of colloid-based porous materials and their uses
Phillips, K. R., England, G. T., Sunny, S., Shirman, E., Shirman, T., Vogel, N., & Aizenberg, J. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00533g · Cited by 282
Nanoparticle-Hydrogel Composites: From Molecular Interactions to Macroscopic Behavior
Dannert, C., Stokke, B. T., & Dias, R. S. (2019) · Polymers · doi:10.3390/polym11020275 · Cited by 261
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Photonic Crystals in Bioassays
Zhao, Y., Zhao, X., & Gu, Z. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201000098 · Cited by 255
Two-Dimensional Photonic Crystal Chemical and Biomolecular Sensors
Cai, Z., Smith, N. L., Zhang, J.-T., & Asher, S. A. (2015) · Analytical Chemistry · doi:10.1021/ac504679n · Cited by 216
Self-citationYetisen, A. K., Butt, H., Volpatti, L. R., Pavlichenko, I., Humar, M., Kwok, S. J. J., Koo, H., Kim, K. S., Naydenova, I., Khademhosseini, A., et al. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.10.005 · Cited by 192
Metadata
- Authors
- Sharma, A. C., Jana, T., Kesavamoorthy, R., Shi, L., Virji, M. A., Finegold, D. N., & Asher, S. A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-02-12
- Volume
- 126
- Issue
- 9
- Pages
- 2971-2977
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1974665855
- Cited by
- 304
- References
- 14
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.