The DOI matches its Crossref record.
A Paramagnetic CEST Agent for Imaging Glucose by MRI
Abstract
The europium(III) complex of a DOTA-tetraamide ligand (DOTA = 1,4,7,10-tetraazacyclododecane-N,N',N' ',N' ''-tetraacetic acids) containing two phenyl boronate pendent arms binds glucose reversibly with an association constant of 383 M-1 at pH 7. Glucose binding results in slowing of water exchange between a single Eu(III)-bound water molecule and bulk water, and this can be imaged by MRI using chemical exchange saturation transfer (CEST) imaging sequence. This metabolite-responsive paramagnetic CEST agent responds to changes in glucose over the physiologically important range (0-20 mM), and thus it offers the possibility of high-sensitivity MR imaging glucose in tissues using bulk water protons as antenna.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lanthanide Probes for Bioresponsive Imaging
Heffern, M. C., Matosziuk, L. M., & Meade, T. J. (2014) · Chemical Reviews · doi:10.1021/cr400477t · Cited by 1,202
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Classification and basic properties of contrast agents for magnetic resonance imaging
Geraldes, C. F. G. C., & Laurent, S. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.265 · Cited by 541
Chemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
Alternatives to Gadolinium-Based Metal Chelates for Magnetic Resonance Imaging
Viswanathan, S., Kovacs, Z., Green, K. N., Ratnakar, S. J., & Sherry, A. D. (2010) · Chemical Reviews · doi:10.1021/cr900284a · Cited by 439
Self-citation
Metadata
- Authors
- Zhang, S., Trokowski, R., & Sherry, A. D.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-11-20
- Volume
- 125
- Issue
- 50
- Pages
- 15288-15289
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1965595965
- Cited by
- 190
- References
- 0
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Paramagnetic CEST Agent for Imaging Glucose by MRI. https://app.cochat.ai/papers/10.1021/ja038345f
- The paper
- Zhang, S., Trokowski, R., & Sherry, A. D. (2003). A Paramagnetic CEST Agent for Imaging Glucose by MRI. Journal of the American Chemical Society. https://doi.org/10.1021/ja038345f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.