The DOI matches its Crossref record.
Interpretation of Protein Adsorption: Surface-Induced Conformational Changes
Abstract
Protein adhesion plays a major role in determining the biocompatibility of materials. The first stage of implant integration is the adhesion of protein followed by cell attachment. Surface modification of implants (surface chemistry and topography) to induce and control protein and cell adhesion is currently of great interest. This communication presents data on protein adsorption (bovine serum albumin and fibrinogen) onto model hydrophobic (CH(3)) and hydrophilic (OH) surfaces, investigated using a quartz crystal microbalance (QCM) and grazing angle infrared spectroscopy. Our data suggest that albumin undergoes adsorption via a single step whereas fibrinogen adsorption is a more complex, multistage process. Albumin has a stronger affinity toward the CH(3) compared to OH terminated surface. In contrast, fibrinogen adheres more rapidly to both surfaces, having a slightly higher affinity toward the hydrophobic surface. Conformational assessment of the adsorbed proteins by grazing angle infrared spectroscopy (GA-FTIR) shows that after an initial 1 h incubation few further time-dependent changes are observed. Both proteins exhibited a less organized secondary structure upon adsorption onto a hydrophobic surface than onto a hydrophilic surface, with the effect observed greatest for albumin. This study demonstrates the ability of simple tailor-made monochemical surfaces to influence binding rates and conformation of bound proteins through protein-surface interactions. Current interest in biocompatible materials has focused on surface modifications to induce rapid healing, both of implants and for wound care products. This effect may also be of significance at the next stage of implant integration, as cell adhesion occurs through the surface protein layer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Walkey, C. D., & Chan, W. C. W. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15233e · Cited by 1,758
Understanding enzyme immobilisation
Hanefeld, U., Gardossi, L., & Magner, E. (2009) · Chem. Soc. Rev. · doi:10.1039/b711564b · Cited by 1,237
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Effects of surface wettability and contact time on protein adhesion to biomaterial surfaces
Xu, L.-C., & Siedlecki, C. A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.032 · Cited by 715
Biocompatible polymer materials: Role of protein–surface interactions
Chen, H., Yuan, L., Song, W., Wu, Z., & Li, D. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.006 · Cited by 706
Metadata
- Authors
- Roach, P., Farrar, D., & Perry, C. C.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-05-13
- Volume
- 127
- Issue
- 22
- Pages
- 8168-8173
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2044252957
- Cited by
- 1,479
- References
- 0
- FWCI
- 18.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interpretation of Protein Adsorption: Surface-Induced Conformational Changes. https://app.cochat.ai/papers/10.1021/ja042898o
- The paper
- Roach, P., Farrar, D., & Perry, C. C. (2005). Interpretation of Protein Adsorption: Surface-Induced Conformational Changes. Journal of the American Chemical Society. https://doi.org/10.1021/ja042898o
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.