The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Magnetic, Electronic, and Structural Characterization of Nonstoichiometric Iron Oxides at the Nanoscale
Abstract
We have investigated the structural, magnetic, and electronic properties of nonstoichiometric iron oxide nanocrystals prepared by decomposition of iron(II) and iron(0) precursors in the presence of organic solvents and capping groups. The highly uniform, crystalline, and monodisperse nanocrystals that were produced enabled a full structural and compositional survey by electron microscopy and X-ray diffraction. The complex and metastable behavior of nonstoichiometric iron oxide (wüstite) at the nanoscale was studied by a combination of Mossbauer spectroscopy and magnetic characterization. Deposition from hydrocarbon solvents with subsequent self-assembly of iron oxide nanocrystals into superlattices allowed the preparation of continuous thin films suitable for electronic transport measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Fluctuations of a Single-Domain Particle
Brown, W. F. (1963) · Physical Review · doi:10.1103/physrev.130.1677 · Cited by 3,374
Drying-Mediated Self-Assembly of Nanoparticles
Rabani, E., Reichman, D. R., Geissler, P. L., & Brus, L. E. (2003) · Nature · doi:10.1038/nature02087 · Cited by 913
Vorotilov, K. A., Yanovskaya, M. I., Turevskaya, E. P., & Sigov, A. S. (1999) · Journal of Sol-Gel Science and Technology · doi:10.1023/a:1008776120997 · Cited by 51
Cited by
Exchange bias in nanostructures
Nogués, J., Sort, J., Langlais, V., Skumryev, V., Suriñach, S., Muñoz, J. S., & Baró, M. D. (2005) · Physics Reports · doi:10.1016/j.physrep.2005.08.004 · Cited by 1,925
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Cutler, J. I., Auyeung, E., & Mirkin, C. A. (2012) · Journal of the American Chemical Society · doi:10.1021/ja209351u · Cited by 1,119
Surface functionalization of nanoparticles for nanomedicine
Mout, R., Moyano, D. F., Rana, S., & Rotello, V. M. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15294k · Cited by 802
Ferrite-based magnetic nanofluids used in hyperthermia applications
Sharifi, I., Shokrollahi, H., & Amiri, S. (2012) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2011.10.017 · Cited by 759
Metadata
- Authors
- Redl, F. X., Black, C. T., Papaefthymiou, G. C., Sandstrom, R. L., Yin, M., Zeng, H., Murray, C. B., & O'Brien, S. P.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-10-16
- Volume
- 126
- Issue
- 44
- Pages
- 14583-14599
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2069187748
- Cited by
- 412
- References
- 3
- FWCI
- 11.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.