The DOI matches its Crossref record.
Catalytic Nanomotors: Autonomous Movement of Striped Nanorods
Abstract
Rod-shaped particles, 370 nm in diameter and consisting of 1 microm long Pt and Au segments, move autonomously in aqueous hydrogen peroxide solutions by catalyzing the formation of oxygen at the Pt end. In 2-3% hydrogen peroxide solution, these rods move predominantly along their axis in the direction of the Pt end at speeds of up to 10 body lengths per second. The dimensions of the rods and their speeds are similar to those of multiflagellar bacteria. The force along the rod axis, which is on the order of 10(-14) N, is generated by the oxygen concentration gradient, which in turn produces an interfacial tension force that balances the drag force at steady state. By solving the convection-diffusion equation in the frame of the moving rod, it was found that the interfacial tension force scales approximately as SR(2)gamma/muDL, where S is the area-normalized oxygen evolution rate, gamma is the liquid-vapor interfacial tension, R is the rod radius, mu is the viscosity, D is the diffusion coefficient of oxygen, and L is the length of the rod. Experiments in ethanol-water solutions confirmed that the velocity depends linearly with the product Sgamma, and scaling experiments showed a strong dependence of the velocity on R and L. The direction of motion implies that the gold surface is hydrophobic under the conditions of the experiment. Tapping-mode AFM images of rods in air-saturated water show soft features that are not apparent in images acquired in air. These features are postulated to be nanobubbles, which if present in hydrogen peroxide solutions, would account for the observed direction of motion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multifunctional Biohybrid Magnetite Microrobots for Imaging-Guided Therapy
Yan, X., Zhou, Q., Vincent, M., Deng, Y., Yu, J., Xu, J., Xu, T., Tang, T., Bian, L., Wang, Y.-X. J., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aaq1155 · Cited by 893
Biomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Nano/Microscale Motors: Biomedical Opportunities and Challenges
Wang, J., & Gao, W. (2012) · ACS Nano · doi:10.1021/nn3028997 · Cited by 668
Designing phoretic micro- and nano-swimmers
Golestanian, R., Liverpool, T. B., & Ajdari, A. (2007) · New Journal of Physics · doi:10.1088/1367-2630/9/5/126 · Cited by 659
Synthetische molekulare Motoren und mechanische Maschinen
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie · doi:10.1002/ange.200504313 · Cited by 624
Metadata
- Authors
- Paxton, W. F., Kistler, K. C., Olmeda, C. C., Sen, A., St. Angelo, S. K., Cao, Y., Mallouk, T. E., Lammert, P. E., & Crespi, V. H.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-09-21
- Volume
- 126
- Issue
- 41
- Pages
- 13424-13431
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2069079436
- Cited by
- 2,128
- References
- 0
- FWCI
- 17.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Catalytic Nanomotors: Autonomous Movement of Striped Nanorods. https://app.cochat.ai/papers/10.1021/ja047697z
- The paper
- Paxton, W. F., Kistler, K. C., Olmeda, C. C., Sen, A., St. Angelo, S. K., Cao, Y., Mallouk, T. E., Lammert, P. E., & Crespi, V. H. (2004). Catalytic Nanomotors: Autonomous Movement of Striped Nanorods. Journal of the American Chemical Society. https://doi.org/10.1021/ja047697z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.