The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fluorescence Detection of DNA by the Catalytic Activation of an Aptamer/Thrombin Complex
Abstract
A conjugate consisting of a thrombin aptamer tethered to the thrombin, Th, with a sensing nucleic acid (1) is used for the optical detection of DNA. The thrombin/aptamer complex blocks the biocatalytic functions of Th. Hybridization of the analyte DNA (2) to the sensing nucleic acid 1 yields a rigid duplex that detaches the aptamer from Th, a process that activates the protein toward the hydrolysis of bis(p-tosyl-Gly-Pro-Arg)-R110 (3) to the rhodamine 110 fluorophore (4). The system allows the DNA sensing with a sensitivity limit of 1 x 10-8 M. The aptamer/Th conjugate is also immobilized on glass slides for the optical detection of DNA. The dissociation of the aptamer/Th complex upon hybridization and the subsequent dehybridization of the duplex and the regeneration of the catalytically inactive Th/aptamer complex duplicate machinery functions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of protein using bicinchoninic acid
Smith, P. K., Krohn, R. I., Hermanson, G. T., Mallia, A. K., Gartner, F. H., Provenzano, M. D., Fujimoto, E. K., Goeke, N. M., Olson, B. J., & Klenk, D. C. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90442-7 · Cited by 18,482
Cited by
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
Self-citationWang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Self-citationNucleic Acid Based Molecular Devices
Krishnan, Y., & Simmel, F. C. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.200907223 · Cited by 572
Wei, H., Li, B., Li, J., Wang, E., & Dong, S. (2007) · Chemical Communications · doi:10.1039/b707642h · Cited by 472
Isothermal amplified detection of DNA and RNA
Yan, L., Zhou, J., Zheng, Y., Gamson, A. S., Roembke, B. T., Nakayama, S., & Sintim, H. O. (2014) · Molecular BioSystems · doi:10.1039/c3mb70304e · Cited by 446
Metadata
- Authors
- Pavlov, V., Shlyahovsky, B., & Willner, I.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-04-15
- Volume
- 127
- Issue
- 18
- Pages
- 6522-6523
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1995676995
- Cited by
- 160
- References
- 1
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence Detection of DNA by the Catalytic Activation of an Aptamer/Thrombin Complex. https://app.cochat.ai/papers/10.1021/ja050678k
- The paper
- Pavlov, V., Shlyahovsky, B., & Willner, I. (2005). Fluorescence Detection of DNA by the Catalytic Activation of an Aptamer/Thrombin Complex. Journal of the American Chemical Society. https://doi.org/10.1021/ja050678k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.