The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Bioresponsive Hydrogel Microlenses
Abstract
We report investigations of bioresponsive hydrogel microlenses as a new protein detection technology. Stimuli-responsive poly(N-isopropylacrylamide-co-acrylic acid) (pNIPAm-co-AAc) microgels have been synthesized via free-radical precipitation polymerization. These hydrogel microparticles were then functionalized with biotin via EDC coupling. Hydrogel microlenses were prepared from the particles via Coulombic assembly onto a silane-modified glass substrate. Arrays containing both pNIPAm-co-AAc microgels (as an internal control) and biotinylated pNIPAm-co-AAc microgels were then used to detect multivalent binding of both avidin and polyclonal anti-biotin. Protein binding was determined by monitoring the optical properties of the microlenses using a brightfield optical microscopy technique. The microlens method is shown to be very specific for the target protein, with no detectable interference from nonspecific protein binding. Finally, the reversibility of the hydrogel microlens assay has been studied in the case of anti-biotin to determine the potential application of the microlens assay technology in a displacement-type assay. These results suggest that the microlens method may be an appropriate one for label-free detection of proteins or small molecules via displacement of tethered protein--ligand pairs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198
Cited by
From design to applications of stimuli-responsive hydrogel strain sensors
Zhang, D., Ren, B., Zhang, Y., Xu, L., Huang, Q., He, Y., Li, X., Wu, J., Yang, J., Chen, Q., et al. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02692d · Cited by 199
Yetisen, A. K., Butt, H., Volpatti, L. R., Pavlichenko, I., Humar, M., Kwok, S. J. J., Koo, H., Kim, K. S., Naydenova, I., Khademhosseini, A., et al. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.10.005 · Cited by 192
Metadata
- Authors
- Kim, J., Nayak, S., & Lyon, L. A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-06-10
- Volume
- 127
- Issue
- 26
- Pages
- 9588-9592
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2054016004
- Cited by
- 278
- References
- 1
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioresponsive Hydrogel Microlenses. https://app.cochat.ai/papers/10.1021/ja0519076
- The paper
- Kim, J., Nayak, S., & Lyon, L. A. (2005). Bioresponsive Hydrogel Microlenses. Journal of the American Chemical Society. https://doi.org/10.1021/ja0519076
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.